Clinical Evaluation of a Cochlear Implant Sound Processor

NCT04237207 — Not applicable, Completed, 22 participants, Advanced Bionics

ClinicalTrials Daily  ·  Areas  ·  Conditions  ·  Drugs  ·  Sponsors  ·  

Evaluation of AutoSense OS on a Cochlear Implant Sound Processor Programmed With Target CI Fitting Software in Adult Users of the HiResolution Bionic Ear System

RegistryNCT04237207
StatusCompleted
PhaseNot applicable
Study typeInterventional; non randomized, parallel, masking: none, treatment
Enrollment22 (Actual)
SponsorAdvanced Bionics (Industry)
ConditionsHearing Loss, Ear Diseases, Hearing Disorders, Otorhinolaryngologic Diseases
InterventionsNaída Cochlear Implant Q90 sound processor (Naida CI Q90) & software, 301-M062 sound processor & software (Device)
Datesstart 2019-12-17, primary completion 2020-10-15, completion 2020-10-15, first posted 2020-01-23, last updated 2022-05-13
Locations6 sites in United States

Related Papers Related Patents Related Grants Related Experts
All trials for Hearing Loss All trials for Ear Diseases All trials of Naída Cochlear Implant Q90 sound processor (Naida CI Q90) & software All trials of 301-M062 sound processor & software

-Summary

This is a prospective within-subjects repeated-measures study that will enroll 24 adult users implanted with a HiResolution Bionic Ear System (HiRes 90K or newer). Subjects will be assigned to one of two cohorts based on audiometric results at the Baseline visit

Expand all sections  ·  Collapse all

+Detailed description

The overall goal of this clinical study is to demonstrate the safety and efficacy of a cochlear implant sound processor. Hearing outcomes are expected to be similar non-inferior to as compared to the currently approved software and processors. Therefore, the study described herein uses a non-inferiority design to determine whether sentence recognition in quiet and in noise is no worse with the new sound processor than with currently approved software on a Q90 processor.

+Arms and interventions

ArmTypeInterventionsDescription
Aidable Residual Hearing (ARH) CohortOtherDevice: Naída Cochlear Implant Q90 sound processor (Naida CI Q90) & software; Device: 301-M062 sound processor & softwareControl Device followed by experimental Device.
Electric Only (EO) CohortOtherDevice: Naída Cochlear Implant Q90 sound processor (Naida CI Q90) & software; Device: 301-M062 sound processor & softwareControl Device followed by experimental Device.
  • Naída Cochlear Implant Q90 sound processor (Naida CI Q90) & software (Device): Control cochlear implant sound processor
  • 301-M062 sound processor & software (Device): New cochlear implant sound processor

+Outcome measures

Primary outcomes

  • Speech Recognition in Quiet [1 Day]: The primary efficacy endpoints are AzBio sentence recognition scores in quiet at Baseline with the new sound processor as compared to AzBio sentence recognition scores in quiet at Baseline with currently approved software on a Q90 processor. Scores are determined on a scale of 0% to 100% words correct with higher scores indicating a better outcome.

Secondary outcomes

  • Speech Recognition in Noise [1 Day]: Demonstrate that AzBio sentence recognition scores in noise with the new sound processor are no worse than AzBio sentence recognition scores in noise with currently approved software on a Q90 processor. Scores are determined on a scale of 0% to 100% words correct with higher scores indicating a better outcome.
  • Increased Speech Recognition in Noise [1 Day]: Demonstrate increased AzBio sentence recognition scores in noise with the new sound processor when comparing "Omnidirectional" program to AutoSense. Omnidirectional refers to a setting in which the AutoSense feature is not active. Scores are determined on a scale of 0% to 100% words correct with higher scores indicating a better outcome.

+Eligibility

Sex: All, ages: 18 Years to any

General Inclusion Criteria:

* Ability to provide Informed Consent
* 18 years of age or older
* Unilateral user of a HiResolutionTM Bionic Ear System (HiRes 90KTM, HiRes 90KTM Advantage, HiResTM Ultra, HiResTM Ultra 3D), including bilaterally implanted subjects that only use one implant in their everyday listening modality
* Minimum of 6 months of CI experience
* Having used a Naída CI Q70 or a Naída CI Q90 as their primary processor for a minimum of one month
* Presently using a current steering strategy
* At least moderate open-set speech recognition abilities with implant alone, as defined by achieving a score of ≥ 60% words correct in the AzBio in quiet test using the Naída CI Q90 research processor
* English language proficiency as determined by the investigator
* Willingness to use a BTE processor for the duration of the study

ARH Arm Inclusion Criteria

* Residual low frequency hearing sensitivity (pure tone average of < 70 dB HL for 125, 250, and 500 Hz) and a severe-to-profound high-frequency sensorineural hearing loss (pure tone average of ≥ 70 dB HL for 1,000, 2,000, 3000, 4,000, and 8,000 Hz) in the implanted ear
* Willingness to use an in-canal acoustic earhook for the duration of the study

EO Arm Inclusion Criteria

• Severe-to-profound sensorineural hearing loss in the low (pure tone average of ≥ 70 dB HL for 125, 250, and 500 Hz) and high frequencies (pure tone average ≥ 70 dB HL for 1,000, 2,000, 3000, 4,000, and 8,000 Hz) in the implanted ear

Exclusion Criteria:

* Unrealistic expectations regarding potential benefits, risks and limitations of the investigational device as determined by the investigator
* Unwillingness or physical / cognitive inability of subject to comply with all investigational requirements as determined by the investigator

+Posted results

Participant flow

MilestoneElectric Only (EO) CohortAidable Residual Hearing (ARH) Cohort
Started1012
Completed1012
Not completed00

Outcome results

  • Speech Recognition in Quiet (Primary), Mean, percentage of correct words: EO Cohort 88.31 +/- 5.817; ARH Cohort 89.39 +/- 10.535 (p 0.0010)
  • Speech Recognition in Noise (Secondary), Mean, percentage of correct word responses: EO Cohort 52.95 +/- 31.163; ARH Cohort 66.04 +/- 25.939 (p 0.0010)
  • Increased Speech Recognition in Noise (Secondary), Mean, percentage of correct words recognized: EO Cohort 42.93 +/- 30.801; ARH Cohort 51.37 +/- 28.604 (p <0.0001)

Adverse events

Time frame: AEs were recorded and tracked between completion of the informed consent form (signed and dated) and two weeks after the participant's last study visit. The total period is up to 5 weeks.

ArmDeathsSerious adverse eventsOther adverse events
EO Cohort0/10 (0.0%)0/10 (0.0%)2/10 (20.0%)
ARH Cohort0/12 (0.0%)0/12 (0.0%)1/12 (8.3%)

Other adverse events by term

TermOrgan systemEO CohortARH Cohort
Patient discomfortProduct Issues0/101/12
Upper RespiratoryInfections and infestations1/100/12
Sprained ankleMusculoskeletal and connective tissue disorders1/100/12

Limitations and caveats: Due to clinic closures related to the COVID-19 pandemic, total enrollment in the EO Cohort was 10 subjects instead of 12.

+Locations (6)

FacilityCityCountryStatus
University of Colorado Anschutz Medical CampusAurora, ColoradoUnited States
Tampa Bay Hearing and Balance CenterTampa, FloridaUnited States
Midwest Ear Institute/St. Luke's Health SystemKansas City, MissouriUnited States
Washington University Medical CenterSt Louis, MissouriUnited States
Vanderbilt University Medical CenterNashville, TennesseeUnited States
Austin Ear, Nose & Throat ClinicAustin, TexasUnited States

+Study documents