TrialReader


Safety and Performance of the Trialign Percutaneous Tricuspid Valve Annuloplasty System (PTVAS)

NCT03225612 — Not applicable, Unknown, 60 participants, Mitralign, Inc.

ClinicalTrials Daily  ·  Areas  ·  Conditions  ·  Drugs  ·  Sponsors  ·  

Safety and Performance of the Trialign Percutaneous Tricuspid Valve Annuloplasty System (PTVAS) for Symptomatic Chronic Functional Tricuspid Regurgitation

RegistryNCT03225612, acronym SCOUT-II
StatusUnknown
PhaseNot applicable
Study typeInterventional; na, single group, masking: none, treatment
Enrollment60 (Estimated)
SponsorMitralign, Inc. (Industry); collaborators: Genae, Regulatory and Clinical Research Institute Inc, CardioVascular Research Foundation, Korea
ConditionsChronic Symptomatic Functional Tricuspid Regurgitation, Tricuspid Valve Insufficiency, Heart Valve Disease
InterventionsMitralign Percutaneous Tricuspid Valve Annuloplasty System (PTVAS) (Device)
Datesstart 2017-05-22, primary completion 2018-06-01 (estimated), completion 2022-11-01 (estimated), first posted 2017-07-21, last updated 2018-02-07
Locations11 sites in Germany, Italy, Netherlands, Portugal

Related Papers Related Patents Related Grants Related Experts
AI Assistant Save
All trials for Chronic Symptomatic Functional Tricuspid Regurgitation All trials for Tricuspid Valve Insufficiency All trials of Mitralign Percutaneous Tricuspid Valve Annuloplasty System (PTVAS)

-Summary

The purpose of this study is to assess the safety and performance of the Trialign System for the treatment of symptomatic chronic functional tricuspid regurgitation (FTR) in patients with a minimum of moderate tricuspid regurgitation.

The procedure will be performed with the PTVAS device using a non-surgical percutaneous approach to tricuspid valve repair in patients who have FTR with a minimum of moderate tricuspid regurgitation.

Expand all sections  ·  Collapse all

+Detailed description

A prospective, single-arm, multi-center study, enrolling symptomatic patients with chronic functional tricuspid regurgitation. The study will include up to 60 subjects from up to 15 sites in Europe and the United States. Follow-up evaluations will be conducted through 5 years post implantation.

+Arms and interventions

ArmTypeInterventionsDescription
Open LabelExperimentalDevice: Mitralign Percutaneous Tricuspid Valve Annuloplasty System (PTVAS)Non-randomized, open label clinical study that intends to treat up to 60 subjects with the Mitralign Percutaneous Tricuspid Valve Annuloplasty System (PTVAS) using standard of care techniques and services that are typically used for structural heart procedures.
  • Mitralign Percutaneous Tricuspid Valve Annuloplasty System (PTVAS) (Device): Mitralign Percutaneous Tricuspid Valve Annuloplasty System (PTVAS) is delivered by a percutaneous transcatheter procedure. The Trialign PTVAS procedure utilizes catheters and wires to deliver up to two sets of pledgeted sutures across the tricuspid annulus near the septal/posterior and the posterior/anterior commissures. Each set of implants is pulled together to plicate the posterior tricuspid annulus.

+Outcome measures

Primary outcomes

  • Incidence of all-cause mortality at 30 days. [30-days]: Incidence of all-cause mortality at 30 days.

Secondary outcomes

  • Technical success [30 Days]: Technical success, defined as freedom from death at 30 days with: * successful access, delivery and retrieval of the device delivery system; * deployment and correct positioning of the intended device(s) which is maintained and; * no need for additional unplanned or emergency surgery or re-intervention related to the device or access procedure
  • Echocardiographic variable: tenting height (maximum, any view) [Change from Baseline at 30 days]: Echocardiographic variables assessed by the Echocardiographic Core Lab at baseline and 30-days reflecting the severity of tricuspid pathology and the response to the Trialign device
  • Echocardiographic variable: tenting area (maximum, any view) [Change from Baseline at 30 days]: Echocardiographic variable assessed by the Echocardiographic Core Lab at baseline and 30-days reflecting the severity of tricuspid pathology and the response to the Trialign device
  • Echocardiographic variable: Quantification of tricuspid valve and annular area (maximum, any view) [Change from Baseline at 30 days]: Echocardiographic variable assessed by the Echocardiographic Core Lab at baseline and 30-days reflecting the severity of tricuspid pathology and the response to the Trialign device
  • Tricuspid regurgitation as determined by echocardiographic methods [Change from Baseline at 30 days]: As measured by the PISA method and the Quantitative Flow method
  • Percent tricuspid regurgitation from baseline to 30-days [Change from Baseline at 30 days]: Percent tricuspid regurgitation from baseline to 30-days
  • Adverse Events [Up to 60 months post procedure]: Rate of adverse events, including serious adverse events
  • New York Heart Association (NYHA) classification [Change from Baseline at discharge and then 1, 3, 6, 12, 24, 36, 48 and 60 months post procedure]: Change in New York Heart Association (NYHA) classification
  • Six-Minute Walk Test (6MWT) [Change from Baseline at discharge and then 1, 3, 6, 12, 24, 36, 48 and 60 months post procedure]: Change in the Six-Minute Walk Test (6MWT)
  • Minnesota Living with Heart Failure Questionnaire (MLWHF) [Change from Baseline at discharge and then 1, 3, 6, 12, 24, 36, 48 and 60 months post procedure]: Score on the Minnesota Living with Heart Failure Questionnaire (MLWHF)
  • EuroQol Five Dimensions Questionnaire (EQ-5D) [Change from Baseline at discharge and then 1, 3, 6, 12, 24, 36, 48 and 60 months post procedure]: Score on the EuroQol Five Dimensions Questionnaire (EQ-5D)

+Eligibility

Sex: All, ages: 18 Years to 85 Years

Inclusion Criteria:

* Chronic functional tricuspid regurgitation (FTR) with a minimum of moderate tricuspid regurgitation;
* ≥18 and ≤85 years old;
* NYHA II, III, or ambulatory IV;
* Symptomatic despite Guideline Directed medical Therapy (GDMT), at minimum, patient on diuretic use;
* patient is at high risk for open heart valve surgery
* LVEF ≥35%
* Tricuspid valve annular diameter ≤55 mm (or 29 mm/m\^2)

Exclusion Criteria:

* Pregnant or lactating female;
* Severe uncontrolled hypertension (SBP ≥ 180 mmHg and/or DBP ≥ 110 mmHg);
* Previous tricuspid valve repair or replacement;
* Severe coronary artery disease;
* MI or known unstable angina within the 30-days prior to the index procedure;
* Any PCI within 30 days prior to the index procedure or planned 3 months post the index procedure;
* Chronic oral steroid use (≥6 months);
* Life expectancy of less than 12-months

+Locations (11)

FacilityCityCountryStatus
Vivantes Klinikum Am UrbanBerlinGermanyRecruiting
Herzzentrum Brandenburg in BernauBernau bei BerlinGermanyRecruiting
CardioVascular Center FrankfurtFrankfurtGermanyRecruiting
Medizinisches Versorgungszentrum Prof. Mathey, Prof. Schofer GmbHHamburgGermanyRecruiting
Herzzentrum Leipzig - UniversitätsklinikLeipzigGermanyRecruiting
German Heart Center MunichMunichGermanyRecruiting
Ospedale San RaffaeleMilanItalyRecruiting
Azienda Ospedaliero Universitaria PisanaPisaItalyRecruiting
Amphia ZiekenhuisBredaNetherlandsNot yet recruiting
University Medical Center GroningenGroningenNetherlandsRecruiting
C. Hospitalar Vila Nova de Gaia/Espinho, E.P.E.PortoPortugalRecruiting

+Investigators

  • Prof. Dr. med Joachim Schofer, Principal investigator, Medizinisches Versorgungszentrum Prof. Mathey, Prof. Schofer GmbH

My Notes