Post Marketing Clinical Study on the Efficacy of Lenses From a New Prescription Protocol

NCT07168564 — Not applicable, Completed, 120 participants, Essilor International

ClinicalTrials Daily  ·  Areas  ·  Conditions  ·  Drugs  ·  Sponsors  ·  

Post Market Clinical Study to Compare Vision With Essilor® AVA™ Lenses Following AVA™ Refraction Protocol to Equivalent Lenses Following Gold Standard Refraction Protocol.

RegistryNCT07168564, acronym ATLANTIC
StatusCompleted
PhaseNot applicable
Study typeInterventional; randomized, crossover, masking: quadruple, supportive care
Enrollment120 (Actual)
SponsorEssilor International (Industry)
ConditionsAmetropia, Refractive Error
InterventionsAVA lenses, Standard lenses (Device)
Datesstart 2025-09-22, primary completion 2026-05-28, completion 2026-05-28, first posted 2025-09-11, last updated 2026-06-09
Locations1 site in United States

Related Papers Related Patents Related Grants Related Experts
AI Assistant Save
All trials for Ametropia All trials for Refractive Error All trials of AVA lenses All trials of Standard lenses

-Summary

The goal of this clinical trial is to assess improvements in visual performance and patient outcomes in wearing new spectacle lenses in general population.

The two spectacle lenses will be compared after two weeks of wearing.

The aims are:

* to evaluate the visual superiority, and quality-of-life implications of Essilor® AVA™ spectacle lenses prescribed after a new subjective refraction protocol named AVA™ protocol.
* to understand the benefits of using a high accuracy instrument and testing sequence over the standard testing sequence in determining a glasses prescription, as well as the overall subjective performance of the resulting glasses.

Expand all sections  ·  Collapse all

+Detailed description

This study aims to evaluate whether finer increments in refraction and spectacle lens manufacturing (0.01D) provide more precise visual corrections compared to the traditional 0.25D steps, and if participants can visually appreciate this difference in the refractive outcome and manufactured lenses. It will assess improvements in visual acuity, comfort, and patient satisfaction, focusing on achieving red-green equality in the duo chrome test and exploring the clinical utility of higher resolution refraction technologies.

Refraction is a critical procedure in eye care that determines the optimal lens power for a focused retinal image. Traditional manual phoropters, the standard for over a century, operate in 0.25D increments but have limitations, as most individuals are sensitive to smaller power variations. Recent technological advancements, such as digital phoropters like the Vision-R™ 800, allow for continuous power adjustments in increments as fine as 0.01D and support manufacturing spectacles in smaller steps.

While these innovations offer theoretical advantages, their clinical impact remains relatively underexplored. This study addresses this gap by comparing traditional and finer increment prescriptions to assess improvements in visual performance and patient outcomes. Results could redefine refraction standards and optimize optometric care practices.

+Arms and interventions

ArmTypeInterventionsDescription
First Essilor® AVA™ and then StandardExperimentalDevice: AVA lenses; Device: Standard lensesParticipants are first prescribed for AVA™ protocol and then for Standard protocol . Patients will first wear the Essilor® AVA™ lenses during 2 weeks. Then, after a washout period of 2 weeks, patients will wear the Standard lenses during 2 weeks.
First Standard then Essilor® AVA™ExperimentalDevice: AVA lenses; Device: Standard lensesParticipants are first prescribed for Standard protocol and then for AVA™ protocol . Patients will first wear the Standard lenses during 2 weeks. Then, after a washout period of 2 weeks, patients will wear the Essilor® AVA™ lenses during 2 weeks.
  • AVA lenses (Device): Participants are prescribed to receive AVA lenses through the AVA protocol and wear these lenses during 2 weeks.
  • Standard lenses (Device): Participants are prescribed to receive Standard lenses through the Gold standard protocol and wear these lenses during 2 weeks.

+Outcome measures

Primary outcomes

  • Vision correction preference [through study completion, an average of 8 weeks]: Proportion of subjects preferring vision correction option between Essilor® AVA™ lenses and the alternative vision correction solution

Secondary outcomes

  • Subjective Binocular Vision Quality [immediately after the intervention, and through study completion, an average of 8 weeks]: Scores of self-reported Subjective Binocular Vision Quality questionnaire OU (0-100 rating) at Distance vision, Near work and Overall Quality of Vision.
  • Subjective Binocular Vision [immediately after the intervention, and through study completion, an average of 8 weeks]: P-value of superiority Wilcoxon signed rank test comparing the Scores regarding Subjective Binocular Vision obtained with Essilor® AVA™ lenses and with Essilor® non-AVA™ lenses
  • Accuracy of refraction [immediately after the intervention, and through study completion, an average of 8 weeks.]: Scores of self-reported perceived accuracy of refraction OU (0-100 rating) obtained with AVA™ Smart program and with standard refraction.
  • accuracy of refraction [immediately after the intervention, and through study completion, an average of 8 weeks.]: P-value of superiority Wilcoxon signed rank test comparing the Scores of self-reported perceived accuracy of refraction OU (0-100 rating) obtained with AVA™ Smart program and with standard refraction
  • perceived refraction experience [immediately after the intervention]: Score of self-reported perceived refraction experience of refraction OU (0-100 rating) obtained with AVA™ Smart program and with standard refraction.
  • Refraction experience accuracy of refraction [through study completion, an average of 8 weeks.]: P-value of superiority Wilcoxon signed rank test comparing the Scores of self-reported refraction experience accuracy of refraction OU (0-100 rating) obtained with AVA™ Smart program and with standard refraction.
  • Subjective refraction experience [immediately after intervention]: Score of self-reported Subjective refraction experience with Essilor® AVA™ lenses in following 2 weeks of wear - Comparison in High contrast, high illumination logMAR Visual Acuity (4m, OU (M\&S)) with refractive outcome (superiority test)
  • Subjective Vision Quality with Essilor® AVA™ lenses [immediately after intervention, through study completion, an average of 8 weeks.]: P-value of superiority Wilcoxon signed rank test comparing the Scores of self-reported Subjective Vision Quality with Essilor® AVA™ lenses in following 2 weeks of wear - Comparison in High contrast, high illumination logMAR Visual Acuity (4m, OU (M\&S)) with refractive outcome (superiority test)
  • Binocular high-contrast, high-illumination logMAR distance visual acuity [immediately after intervention, through completion of study, an average of 8 weeks.]: Binocular high-contrast, high-illumination logMAR distance visual acuity with AVA™ lenses and Vision-R™ 800.
  • binocular high-contrast high-illumination distance visual acuity [immediately after intervention, through completion of study, an average of 8 weeks.]: P-value of superiority Wilcoxon signed rank test comparing binocular high-contrast high-illumination distance visual acuity with the AVA™ Smart Program refraction results and Essilor® AVA™ lenses manufactured from this prescription, over the standard refraction results and corresponding Essilor® non-AVA™ lenses.
  • Binocular low-contrast high-illumination distance logMAR visual acuity [immediately after intervention, through completion of study, an average of 8 weeks.]: Binocular low-contrast high-illumination distance logMAR visual acuity with Essilor® AVA™ lenses and Vision-R 800™.
  • binocular low-contrast high-illumination distance log MAR visual acuity [immediately after intervention, through completion of study, an average of 8 weeks.]: P-value of superiority Wilcoxon signed rank test comparing binocular low-contrast high-illumination distance log MAR visual acuity with the AVA™ Smart Program refraction results and Essilor® AVA™ lenses manufactured from this prescription over the standard refraction results and corresponding Essilor® non-AVA™ lenses
  • Binocular low-contrast low-illumination distance logMAR visual acuity [immediately after intervention, through completion of study, an average of 8 weeks.]: Binocular low-contrast low-illumination distance logMAR visual acuity with Essilor® AVA™ lenses and Vision-R 800™.
  • binocular low-contrast low-illumination distance log MAR visual acuity [immediately after intervention, through completion of study, an average of 8 weeks.]: P-value of superiority Wilcoxon signed rank test comparing binocular low-contrast low-illumination distance log MAR visual acuity with the AVA™ Smart Program refraction results and Essilor® AVA™ lenses manufactured from this prescription over the standard refraction results and corresponding Essilor® non-AVA™ lenses.
  • Binocular distance contrast sensitivity [immediately after intervention, through completion of study, an average of 8 weeks.]: Binocular distance contrast sensitivity (4m, OU) with refractive outcome.
  • Binocular distance contrast sensitivity [immediately after intervention, through completion of study, an average of 8 weeks.]: P-value of superiority Wilcoxon signed rank test comparing Binocular distance contrast sensitivity with the AVA™ Smart Program refraction results and Essilor® AVA™ lenses manufactured from this prescription over the standard refraction results and Essilor® non-AVA™ lenses.
  • binocular stereo acuity [immediately after intervention]: Summarize binocular stereo acuity with AVA™ lenses and Vision-R 800™
  • binocular stereo acuity [immediately after intervention]: Mean difference in binocular stereo acuity (4m, Vision-R 800™ system) with the AVA™ Smart Program refraction results and prescribed Essilor® AVA™ lenses over the standard refraction results and corresponding Essilor® non-AVA™ lenses.
  • Duochrome Equality [immediately after intervention]: Summarize relative frequency of Duochrome Equality OD, OS in distance refractive outcomes
  • relative frequency of Duochrome Equality [through study completion, an average of 8 weeks.]: P-value of McNemar test comparing the relative frequency of Duochrome Equality OD, OS with AVA™ Smart Program refraction and with the standard refraction.
  • 5-point Likert [through study completion, an average of 8 weeks.]: P-value of Wilcoxon signed rank test comparing the relative frequencies of responses on a 5-point Likert (distance, near) scale preferring AVA™ Smart program refraction and/or standard refraction assessment.
  • relative frequencies of scores [through study completion, an average of 8 weeks.]: P-value of Wilcoxon signed rank test comparing the relative frequencies of scores assessing lenses Essilor® AVA™ and non-AVA™ lenses following masked in-office trial (5-point Likert; Distance vision, Near work (phone reading), Computer, Across a room, Visual Comfort, Color Vision/Contrast Depth perception, Overall Quality of Vision, Overall satisfaction)
  • scores assessing lenses in Subjective Vision Quality [through study completion, an average of 8 weeks.]: P-value of Wilcoxon signed rank test comparing the relative frequencies of scores assessing lenses Essilor® AVA™/non AVA™ lenses in Subjective Vision Quality - OU (0-100 rating; Day driving, Night driving, Computer, across a room, Visual Comfort, Color Vision/Contrast, Depth Perception, Overall Quality of Vision, Adaptation speed, Ease of Adaptation, Overall satisfaction) following two weeks of wear.
  • scores assessing lenses evaluated by Patient (Preference) [through study completion, an average of 8 weeks.]: P-value of Wilcoxon signed rank test comparing the relative frequencies of scores assessing Essilor® AVA™/non-AVA™ lenses evaluated by Patient (Preference) - better confidence in refraction, higher satisfaction with refraction

+Eligibility

Sex: All, ages: 18 Years to 70 Years

Inclusion Criteria:

1. Age between 18 y/o and 70
2. Accepted and signed the consent form
3. Agree to participate in the scheduled visits
4. Best-corrected visual acuity by manifest refraction of +0.10 log MAR (20/25 Snellen) or better in each eye
5. Spherical Equivalent Refractive Error between -10.00 and 10.00 D
6. Possess current wearable and visually functional eyeglasses
7. Agree to wear the assigned frames fitted with the provided lenses for a minimum of 14 days, during 6h/day, equivalent to 42 hours of wearing a week.
8. No binocular vision issues
9. No cataract, grade 2 or greater

   Presbyope subjects: To be eligible for the presbyopic group, individuals need to be (half of the analyzed population):
10. 35-70 years of age, inclusive
11. Currently wearing and adapted to progressive addition lenses

Exclusion Criteria:

1. Less than 18 years or greater than 70 years of age
2. Does not wear spectacles at least 6 hours/day
3. Does not have a wearable pair of glasses with a prescription ≤2 years old
4. Currently or formerly a licensed optometrist, optician, or ophthalmic technician trained in refraction

+Locations (1)

FacilityCityCountryStatus
Clinical Optics Research Lab @ Borish Center for Ophthalmic Research Indiana University School of Optometry Indiana UniversityBloomington, IndianaUnited States

+Publications

  • Kollbaum PS, Jansen ME, Rickert ME. Comparison of patient-reported visual outcome methods to quantify the perceptual effects of defocus. Cont Lens Anterior Eye. 2012 Oct;35(5):213-21. doi: 10.1016/j.clae.2012.05.001. Epub 2012 May 28. PMID 22647932
  • Meyer D, Rickert M, Reed O, Joret P, Kollbaum P. Clinical Comparison of High-resolution and Standard Refractions and Prescriptions. Optom Vis Sci. 2023 Nov 1;100(11):751-760. doi: 10.1097/OPX.0000000000002076. PMID 37861987