Continuous Cardiorespiratory Monitoring in Cystic Fibrosis

NCT04489186 — Not applicable, Completed, 26 participants, Byteflies

ClinicalTrials Daily  ·  Areas  ·  Conditions  ·  Drugs  ·  Sponsors  ·  

Piloting the Clinical Value of Wearable Cardiorespiratory Monitoring for People With Cystic Fibrosis

RegistryNCT04489186
StatusCompleted
PhaseNot applicable
Study typeInterventional; na, single group, masking: none, device feasibility
Enrollment26 (Actual)
SponsorByteflies (Industry); collaborators: University Hospitals Cleveland Medical Center
ConditionsCystic Fibrosis
InterventionsWearable device (Device)
Datesstart 2018-12-01, primary completion 2019-12-31, completion 2019-12-31, first posted 2020-07-28, last updated 2020-07-28
Locations1 site in United States

Related Papers Related Patents Related Grants Related Experts
All trials for Cystic Fibrosis All trials of Wearable device

-Summary

Cystic Fibrosis (CF) is a disease without a primary cure that requires lifelong care and is characterized by pulmonary exacerbations (PEx). Wearable devices could provide a way for long-term monitoring of disease progression and early signs of PEx to intervene as early as possible, thereby improving long-term outcomes.

This in-hospital feasibility study will assess the ability of Byteflies Sensor Dots to collect relevant cardiorespiratory data in people with CF and its compatibility with clinical workflows, 2) identify candidate digital biomarkers, and 3) collect user feedback from patients and healthcare providers.

Expand all sections  ·  Collapse all

+Arms and interventions

ArmTypeInterventionsDescription
All subjectsExperimentalDevice: Wearable deviceSingle arm feasibility study with a wearable device intervention for cardiorespiratory and activity monitoring in subjects with cystic fibrosis.
  • Wearable device (Device), also known as Byteflies Sensor Dot: Multimodal electrocardiography (ECG), bioimpedance (bioZ) and tri-axial accelerometry (ACC) monitoring with a single wearable device (Byteflies Sensor Dot) to derive heart rate, respiratory rate and actigraphy.

+Outcome measures

Primary outcomes

  • Sensor Dot usability [Up to 24 hours]: Assessed via user (healthcare professional and patient) surveys.
  • Sensor Dot data quality [Up to 24 hours]: Evaluated by visual examination of recorded electrocardiography (ECG), bioimpedance (bioZ), and accelerometry (ACC) data.

Secondary outcomes

  • Quality of calculated vital signs: heart rate [Up to 24 hours]: Compare Sensor Dot heart rate (derived from ECG) in beats-per-minute against heart rate as measured by standard hospital equipment.
  • Quality of calculated vital signs: respiratory rate [Up to 24 hours]: Compare Sensor Dot respiratory rate (derived from bioZ) in breaths-per-minute against respiratory rate as measured by standard hospital equipment.
  • Cough detection [Up to 24 hours]: Assess if cough events can be derived from the wearable data, as compared to self-reported outcomes.
  • Screen for candidate digital biomarkers in CF [Up to 24 hours]: Evaluate correlations between the recorded vital sign data (Sensor Dot) and CF severity scores derived from routine pulmonary function testing (PFT, based on Global Lung Function Initiative) and PEx.

+Eligibility

Sex: All, ages: 18 Years to any

Inclusion Criteria:

* ≥ 18 years old
* Confirmed CF diagnosis as determined by a sweat chloride ≥ 60 mmol/L or the presence of two known disease-causing mutations

Exclusion Criteria:

* Inability to provide written informed consent
* A known allergy to any of the used medical adhesives
* Presence of any type of electronic implanted medical device

+Locations (1)

FacilityCityCountryStatus
University Hospitals Cleveland Medical CenterCleveland, OhioUnited States

+Investigators