TrialReader


Safety and Efficacy of Peripheral, Cobalt-chromium Sirolimus Eluting Stent (PERS) Versus Cobalt-chromium Stent (Neptune C)

NCT04323033 — Not applicable, Completed, 40 participants, Balton Sp.zo.o.

ClinicalTrials Daily  ·  Areas  ·  Conditions  ·  Drugs  ·  Sponsors  ·  

Prospective, Randomized Clinical Trial Evaluating Safety and Efficacy of Cobalt-chromium Sirolimus Eluting Stent (PERS) by Balton Versus Cobalt-chromium Stent (Neptune C), to Maintain Patency of Iliac Arteries in Patients Undergoing Peripheral Angioplasty

RegistryNCT04323033, acronym PERS
StatusCompleted
PhaseNot applicable
Study typeInterventional; randomized, parallel, masking: none, treatment
Enrollment40 (Actual)
SponsorBalton Sp.zo.o. (Industry); collaborators: KCRI
ConditionsPeripheral Arterial Disease
InterventionsPERS stent, NEPTUN C stent (Device)
Datesstart 2019-03-13, primary completion 2020-10-31, completion 2021-11-09, first posted 2020-03-26, last updated 2022-03-14
Locations3 sites in Poland

Related Papers Related Patents Related Grants Related Experts
AI Assistant Save
All trials for Peripheral Arterial Disease All trials of PERS stent All trials of NEPTUN C stent

-Summary

The aim of this study is to assess the safety and efficacy of PAD treatment by revascularization with new cobalt-chromium sirolimus stent implantation, which is expandable on balloon PERS (CoCr SES) compared to cobalt-chromium balloon-expandable (Neptun C) stent (CoCr BMS) in patients with symptomatic iliac arteries disease requiring revascularization.

Expand all sections  ·  Collapse all

+Arms and interventions

ArmTypeInterventionsDescription
PERS stentExperimentalDevice: PERS stent20 Patients will receive PERS stent
NEPTUN C stentActive comparatorDevice: NEPTUN C stent20 Patients will receive NEPTUN C stent
  • PERS stent (Device): PERS® is a cobalt-chromium stent, made of cobalt-chromium alloy with drug (Sirolimus) and biodegradable polymer controlling drug elution. The length of the stent is selected to cover the treated lesion with a margin of 5 mm proximal and distal, while the diameter of the stent will be selected based on the QVA measurement (balloon to vessel ratio 1:1).
  • NEPTUN C stent (Device): Neptun C is balloon-expanding cobalt-chromium stent.

+Outcome measures

Primary outcomes

  • Occurrence of MAE [12 months FU]: Occurrence of major adverse event (MAE) in 12 months follow up, defined as death related to stent implantation of procedure, amputation above metatarsus in treated limb due to vascular complication or/and reintervention in treated lesion (TLR).

Secondary outcomes

  • Vessel patency [30 days, 6 months and 12 months FU]: Vessel patency 30 days, 6 and 12 months after the initial procedure assessed by Dupplex Doppler
  • Success of implanting the device [Directly after implantation, at the end of endovascular index procedure]: Success of implanting the device, defined as residual stenosis ≤30% in angiographic assessment.
  • Procedural success [Up to 7 days after procedure]: Procedural success, defined as residual stenosis ≤30% in angiographic assessment and lack of procedurę related SAE.
  • Clinical success [During follow-up visits: 30 days, 6 months and 12 months]: Clinical success, defined as improvement in Rutherford classification for at least 1 point.
  • ABI (ankle-brachial index) change [30 days and 12 months FU]: ABI (ankle-brachial index) change after 30 days and 12 months
  • Mortality rate [30 days, 6 months and 12 months FU]: Mortality rate after 30 days, 6 months and 12 months (cardiovascular deaths)
  • Artery patency in Duplex Doppler USG: Maximum velocity flow [30 days, 6 months and 12 months FU]: Maximum velocity flow assessed by Dupplex Doppler
  • Artery patency in Duplex Doppler USG: % of diameter stenosis [30 days, 6 months and 12 months FU]: % of diameter stenosis (DS in target lesion) assessed by Dupplex Doppler

+Eligibility

Sex: All, ages: 18 Years to any

Inclusion Criteria:

1. De novo lesion or restenosis without previously implanted stent, in a common or external iliac artery with a reference diameter of 5 to 12 mm, length up to 10 cm and stenosis ≥ 50% and ≤ 99% (in quantitative assessment by peripheral angiography), which may be treated with one stent or total occlusion of vessels up to 50 mm long.
2. Ability to cross the lesion with guidewire (assessed during diagnostic angiography).
3. ABI ankle-brachial index <0.9.
4. Signs of lower limb ischemia based on the Rutherford scale in the range from 2 to 4.
5. Age ≥ 18 years.
6. Patient signed informed consent form.

Exclusion Criteria:

1. Life expectancy less than two years.
2. Chronic kidney disease in stage III-V.
3. Lesion in the previously implanted by-pass.
4. Target lesion is a chronic total occlusion of significant length, not eligible for percutaneous revascularization.
5. Acute lower limb ischemia.
6. Stenosis (> 50%) or occlusion proximally to the lesion being treated.
7. Angiographically confirmed thrombus in the lesion to be treated.
8. Treatment requires an atherectomy to deliver stent to treated lesion.
9. Known allergy or hypersensitivity to clopidogrel.
10. Hemorrhagic stroke in the last three months.
11. Contraindications for acetylsalicylic acid (hypersensitivity, hemorrhagic diathesis).
12. Pregnancy or women of childbearing potential not using effective contraception.
13. Active inflammation at the planned access site.

+Locations (3)

FacilityCityCountryStatus
Małopolskie Centrum Sercowo-Naczyniowe PAKS American Heart of Poland S.A.ChrzanówPoland
Samodzielny Publiczny Szpital Kliniczny nr 1LublinPoland
Szpital Eskulap Centrum Leczenia Chorób Serca i NaczyńOsielskoPoland

My Notes