visuALL Field Analyzer (vFA) Compared to Standard Humphrey Automated Perimetry

NCT03804684 — Not applicable, Completed, 72 participants, Wills Eye

ClinicalTrials Daily  ·  Areas  ·  Conditions  ·  Drugs  ·  Sponsors  ·  

How Does the visuALL Field Analyzer (vFA) Compare to Standard Automatic Perimetry (SAP) in Patients With Mild and Moderate Chronic Open Angle Glaucoma (COAG) and Subjects Without Eye Problems?

RegistryNCT03804684
StatusCompleted
PhaseNot applicable
Study typeInterventional; non randomized, parallel, masking: none, diagnostic
Enrollment72 (Actual)
SponsorWills Eye (Other); collaborators: Olleyes, Inc.
ConditionsGlaucoma, Open-Angle
InterventionsStandard Automatic Perimetry Humphrey Field Analyzer, visuALL Field Analyzer (Diagnostic test)
Datesstart 2019-01-08, primary completion 2020-10-20, completion 2020-10-20, first posted 2019-01-15, last updated 2022-06-29
Locations1 site in United States

Related Papers Related Patents Related Grants Related Experts
AI Assistant Save
All trials for Glaucoma, Open-Angle All trials of Standard Automatic Perimetry Humphrey Field Analyzer All trials of visuALL Field Analyzer

-Summary

To determine age-adjusted reference values of the visuALL Field Analyzer (vFA) retinal sensitivity and to assess the repeatability of the measured values and compare them with those measured by a Standard Automatic Perimetry (SAP).

Expand all sections  ·  Collapse all

+Detailed description

Standard Automatic Perimetry (SAP) is the gold standard test for the evaluation of central and peripheral retinal sensitivity to light for detection and monitoring optic nerve diseases such as glaucoma. The current device has its own limitation such as positioning for the duration of the test which makes is hard for older patients especially those with back or other musculoskeletal diseases, artifact of the corrective lenses used to accommodate the patients refractive errors, etc.

Several devices have been developed since the advent of the Octopus Perimeter 3-5 and the Humphrey Field Analyzer (HFA), in an effort to improve the test reliability and patient comfort.

The main goal of this study is to evaluate the repeatability of a novel psychophysical platform that takes advantage of a Head Mounted Device (HMD) with eye tracking capabilities. Other objectives of this study include the development of an initial reference database and comparison of the measured parameters with HFA.

+Arms and interventions

ArmTypeInterventionsDescription
Healthy ControlsExperimentalDiagnostic Test: Standard Automatic Perimetry Humphrey Field Analyzer; Diagnostic Test: visuALL Field AnalyzerHealthy subjects between 21 and 80 years of age with no eye diseases (normal appearing optic nerve and retina, intraocular eye pressure less than 19 millimeters of mercury, normal and reliable standard automatic perimetry, and spherical refraction less than 3 diopters and cylinder correction equal to 2 diopters or less. All subjects will perform Standard Automatic Perimetry Humphrey Field Analyzer and visuALL Field Analyzer to measure peripheral and central visual field.
Mild and Moderate GlaucomaExperimentalDiagnostic Test: Standard Automatic Perimetry Humphrey Field Analyzer; Diagnostic Test: visuALL Field AnalyzerSubjects between 21 and 80 years of age with Mild or Moderate Glaucoma. Eyes will have a reliable standard automatic perimetry with no more than -6 mean deviation (Mild) and between -6 mean and -12 mean deviation (Moderate). Spherical refraction will be less than 3 diopters and cylinder correction equal to 2 diopters or less. All subjects will perform Standard Automatic Perimetry Humphrey Field Analyzer and visuALL Field Analyzer to measure peripheral and central visual field.
  • Standard Automatic Perimetry Humphrey Field Analyzer (Diagnostic test), also known as SAP HFA: Standard Automatic Perimetry (SAP) Humphrey Field Analyzer (HFA) 24-2, Swedish Interactive Threshold Algorithm (SITA) Standard Strategy measures peripheral and central vision in an ophthalmic setting.
  • visuALL Field Analyzer (Diagnostic test), also known as vFA: visuALL Field Analyzer a new portable hardware and software virtual reality system measures peripheral and central vision to improve early detection of glaucoma damage in a non ophthalmic setting.

+Outcome measures

Primary outcomes

  • Mean Retinal Sensitivity From Two Machines [three hours]: Mean (Average) retinal sensitivity to light as measured in decibels in multiple spots across the central and peripheral retina (entire visual field). Higher numbers translate to dimmer light which when detected means better vision.
  • Global Correlation (Agreement Between Two Machines in the Overall Visual Field) [three hours]: Correlation (Agreement) between Humphrey Visual Field and VisuALL retinal sensitivity as measured by mean deviation (light measurement in decibels) in multiple spots across the central and peripheral retina (entire visual field). This is the amount of agreement of the measure threshold, which is the lowest level of light detected in different points across the visual field (overall), between two testing machines.

Secondary outcomes

  • Inferior Nasal Quadrant Correlation (Agreement Between Two Machines in the Inferior Nasal Visual Field) [three hours]: Correlation (Agreement) between Humphrey Visual Field and VisuALL retinal sensitivity as measured by mean deviation (light measurement in decibels) in multiple spots across the inferior nasal visual field. This is the amount of agreement of the measure threshold, which is the lowest level of light detected in different points across the inferior (lower) nasal portion of the visual field, between two testing machines.
  • Superior Hemifield Correlation (Agreement Between Two Machines in the Superior Hemifield Visual Field [three hours]: Correlation (Agreement) between Humphrey Visual Field and VisuALL retinal sensitivity as measured by mean deviation (light measurement in decibels) in multiple spots across the superior (upper) hemifield portion of the visual field. This is the amount of agreement of the measure threshold, which is the lowest level of light detected in different points across the visual field in the superior hemifield, between two testing machines.

+Eligibility

Sex: All, ages: 21 Years to 80 Years, accepts healthy volunteers

Inclusion Criteria:

* age 21 to 80 years
* Healthy subjects with no eye diseases, normal appearing optic nerve and retina, intraocular pressure less than 19 millimeters mercury and normal standard automatic perimetry (SAP).
* mild glaucoma subjects with less than -6 mean deviation
* moderate glaucoma subjects with -6 to -12 mean deviation

Exclusion Criteria:

* spherical refraction outside ± 3.0 diopters and cylinder correction outside 2.0 diopters
* Unreliable SAP (false positives, fixation losses and false negatives greater than 25% and/or observable testing artifacts)
* Unreliable visuALL Field Analyzer (vFA) (greater than 25% false positive, excessive fixation losses)
* SAP abnormality with pattern loss consistent with neurologic and/or other ocular diseases than glaucoma
* Intraocular surgery in study eye (except non-complicated cataract or refractive surgery performed more than 6 months before enrollment and without posterior capsule opacification)
* History of systemic condition known to affect visual function
* History of medication known to affect visual function

+Posted results

Participant flow

MilestoneHealthy ControlsGlaucoma Group
Started2844
Completed2526
Not completed318

Outcome results

  • Mean Retinal Sensitivity From Two Machines (Primary), Mean, decibels: Healthy Controls 29.9 +/- 1.4; Glaucoma Group 24.8 +/- 3.9
  • Global Correlation (Agreement Between Two Machines in the Overall Visual Field) (Primary), Mean, decibels: Healthy Controls 0.5 (0 to 1); Glaucoma Group 0.8 (0 to 1)
  • Inferior Nasal Quadrant Correlation (Agreement Between Two Machines in the Inferior Nasal Visual Field) (Secondary), Mean, decibels: Healthy Controls 0.3 (0 to 1); Glaucoma Group 0.8 (0 to 1)
  • Superior Hemifield Correlation (Agreement Between Two Machines in the Superior Hemifield Visual Field (Secondary), Mean, decibels: Healthy Controls 0.4 (0 to 1); Glaucoma Group 0.6 (0 to 1)

Adverse events

Time frame: 3 hours

ArmDeathsSerious adverse eventsOther adverse events
Healthy Controls0/28 (0.0%)0/28 (0.0%)0/28 (0.0%)
Glaucoma Group0/44 (0.0%)0/44 (0.0%)0/44 (0.0%)

Limitations and caveats: Disadvantages of VisuALL are similar to standard automated perimetry. They rely on patient cooperation and concentration during visual field examination. In addition, the system does not include follow-up analysis. The head-mounted device may not be preferred by subjects with claustrophobic tendencies.

+Locations (1)

FacilityCityCountryStatus
Wills Eye HospitalPhiladelphia, PennsylvaniaUnited States

+Publications

  • Results publication: Razeghinejad R, Gonzalez-Garcia A, Myers JS, Katz LJ. Preliminary Report on a Novel Virtual Reality Perimeter Compared With Standard Automated Perimetry. J Glaucoma. 2021 Jan 1;30(1):17-23. doi: 10.1097/IJG.0000000000001670. PMID 32941320