PRECISION Study: A Prospective, Multi-center Evaluation of Precision, Compression and Performance of a Novel Implanted Continuous Glucose Sensor Using a Next Generation Transmitter and Algorithm
| Registry | NCT03251079, acronym PRECISION |
| Status | Completed |
| Phase | Not applicable |
| Study type | Interventional; na, single group, masking: none, diagnostic |
| Enrollment | 36 (Actual) |
| Sponsor | Senseonics, Inc. (Industry) |
| Conditions | Diabetes Mellitus, Diabetes Mellitus, Type 1, Diabetes Mellitus, Type 2 |
| Interventions | Continuous glucose monitoring system (Device) |
| Dates | start 2017-07-25, primary completion 2018-02-01, completion 2018-02-01, first posted 2017-08-16, last updated 2024-02-12 |
| Locations | 3 sites in United States |
Related Papers Related Patents Related Grants Related Experts
AI Assistant Save
All trials for Diabetes Mellitus All trials for Diabetes Mellitus, Type 1 All trials of Continuous glucose monitoring system
-Summary
The purpose of this multi-center, prospective clinical study is to evaluate the performance of a novel, implanted Senseonics continuous glucose monitoring system (Senseonics CGM System) compared to Yellow Springs Instrument (YSI) glucose analyzer reference standard measurements using a next generation transmitter and algorithm. Other measures evaluated will be the effects of compression on performance and the safety of the Senseonics CGM system.
Expand all sections · Collapse all
+Arms and interventions
| Arm | Type | Interventions | Description |
|---|
| Continuous Glucose Monitoring Device | Experimental | Device: Continuous glucose monitoring system | Senseonics continuous glucose monitoring system |
- Continuous glucose monitoring system (Device), also known as Senseonics continuous glucose monitoring system: Implanted continuous glucose monitoring system
+Outcome measures
Primary outcomes
- Accuracy of CGM System Through 90 Days Post-Insertion (MARD for Paired CGM and Reference Glucose Measurements) [90 days]: The effectiveness endpoint is the mean absolute relative difference (MARD), calculated for all paired Senseonics CGM System and reference glucose measurements through 90 days of Sensor use. MARD is defined as the average of absolute difference of paired Senseonics CGM System and reference glucose readings divided by the reference glucose reading (reference) for all reference glucose values, that is: MARD = ((SUM \| (Glucose)sensor - (Glucose)reference \| / (Glucose)reference ) / n ) x 100%, where n is the total number of CGM and reference glucose pairs after 90 days of sensor use (MARD is a percentage). Lower MARDs indicate higher (better) accuracy.
- Safety Endpoint [90 days]: Incidence of device-related or sensor insertion/removal procedure-related serious adverse events through 90 days post-insertion.
+Eligibility
Sex: All, ages: 18 Years to any
Inclusion Criteria:
1. Adult subjects, age ≥18 years
2. Clinically confirmed diagnosis of diabetes mellitus for ≥1 year
3. Subject has signed an informed consent form and is willing to comply with protocol requirements
Exclusion Criteria:
1. History of severe hypoglycemia in the previous 6 months. Severe hypoglycemia is defined as hypoglycemia resulting in loss of consciousness or seizure
2. History of diabetic ketoacidosis requiring emergency room visit or hospitalization in the previous 6 months
3. Female subjects of childbearing capacity (defined as not surgically sterile or not menopausal for ≥ 1 year) who are lactating or pregnant, intending to become pregnant, or not practicing birth control during the course of the study.
4. A condition preventing or complicating the placement, operation, or removal of the Sensor or wearing of transmitter, including upper extremity deformities or skin condition.
5. Symptomatic coronary artery disease; unstable angina; myocardial infarction, transient ischemic attack or stroke in the past 6 months; uncontrolled hypertension (systolic>160 mm Hg or diastolic >100 mm Hg at time of screening); current congestive heart failure; history of cardiac arrhythmia (benign Premature Atrial Contractions (PACs) and Premature Ventricular Contractions (PVCs) allowed).
Subjects with asymptomatic coronary artery disease (e,g, coronary artery bypass graft (CABG), stent placement or angioplasty) may participate if negative stress test within 1 year prior to screening and written clearance from Cardiologist documented.
6. Hematocrit <30% or >55%
7. History of hepatitis B, hepatitis C, or HIV
8. Current treatment for a seizure disorder unless written clearance by neurologist to participate in study
9. History of adrenal insufficiency
10. Currently receiving (or likely to need during the study period):
immunosuppressant therapy; chemotherapy; anticoagulant/antithrombotic therapy (excluding aspirin); glucocorticoids (excluding ophthalmic or nasal). This exclusion does include the use of inhaled glucocorticoids and the use of topical glucocorticoids (over sensor site only); antibiotic for chronic infection (e.g. osteomyelitis, endocarditis)
11. A condition requiring or likely to require magnetic resonance imaging (MRI)
12. Known topical or local anesthetic allergy
13. Known allergy to glucocorticoids
14. Any condition that in the investigator's opinion would make the subject unable to complete the study or would make it not in the subject's best interest to participate in the study. Conditions include but are not limited to psychiatric conditions, known current or recent alcohol abuse or drug abuse by subject history, a condition that may increase the risk of induced hypoglycemia or risk related to repeated blood testing. Investigator will supply rationale for exclusion
15. Participation in another clinical investigation (drug or device) within 2 weeks prior to screening or intent to participate during the study period
16. The presence of any other active implanted device (as defined further in protocol)
17. The presence of any other CGM sensor or transmitter located in upper arm (other location is acceptable)
+Posted results
Participant flow
| Milestone | Continuous Glucose Monitoring Device |
|---|
| Started | 36 |
| Completed | 35 |
| Not completed | 1 |
Outcome results
- Accuracy of CGM System Through 90 Days Post-Insertion (MARD for Paired CGM and Reference Glucose Measurements) (Primary), Mean, percent: Continuous Glucose Monitoring Device 9.6 (8.9 to 10.4)
- Safety Endpoint (Primary), Number, serious adverse events: Continuous Glucose Monitoring Device 0 (0.0 to 3.5)
Adverse events
Time frame: Through 90 days post Sensor insertion and sensor removal 10-day follow-up (up to 100 days)
| Arm | Deaths | Serious adverse events | Other adverse events |
|---|
| Continuous Glucose Monitoring Device | 0/35 (0.0%) | 3/35 (8.6%) | 15/35 (42.9%) |
Serious adverse events by term
| Term | Organ system | Continuous Glucose Monitoring Device |
|---|
| Other - Gastroenteritis | Gastrointestinal disorders | 1/35 |
| Hypoglycemic episode | Endocrine disorders | 1/35 |
| Other - Wound infection left foot, grade 4 | Musculoskeletal and connective tissue disorders | 1/35 |
Other adverse events by term
| Term | Organ system | Continuous Glucose Monitoring Device |
|---|
| Common Cold | Respiratory, thoracic and mediastinal disorders | 4/35 |
| Sensor Location Site - Pain/Discomfort | Skin and subcutaneous tissue disorders | 2/35 |
| Other - Upper Respiratory Infection | Respiratory, thoracic and mediastinal disorders | 3/35 |
| Headache | Nervous system disorders | 4/35 |
| Other - Pneumonia | Respiratory, thoracic and mediastinal disorders | 1/35 |
| Other - Pilonidal cyst | Skin and subcutaneous tissue disorders | 1/35 |
| Other - Difficulty removing sensor | Skin and subcutaneous tissue disorders | 1/35 |
| Adhesive Patch Location Site - Irritation including redness, excoriation or ulceration | Skin and subcutaneous tissue disorders | 1/35 |
| Other - Darkening of skin at proximal end of sensor | Skin and subcutaneous tissue disorders | 1/35 |
| Other - Vaginal Infection | Reproductive system and breast disorders | 1/35 |
| Other - Dental Caries | General disorders | 1/35 |
| Other - Arthritis | Musculoskeletal and connective tissue disorders | 1/35 |
+Locations (3)
| Facility | City | Country | Status |
|---|
| AMCR Institute Inc. | Escondido, California | United States | |
| Diablo Clinical Research | Walnut Creek, California | United States | |
| Rainier Clinical Research Center | Renton, Washington | United States | |
+Study documents
+Investigators