TrialReader


Superb Microvascular Imaging in Focal Nodular Hyperplasia

NCT02737865 — Not applicable, Completed, 62 participants, Samsung Medical Center

ClinicalTrials Daily  ·  Areas  ·  Conditions  ·  Drugs  ·  Sponsors  ·  

"The Fingerprint: Spoke-wheel Sign" of Focal Nodular Hyperplasia: Assessment of Novel Ultrasound Approach Using Superb Microvascular Imaging Technique

RegistryNCT02737865
StatusCompleted
PhaseNot applicable
Study typeInterventional; na, single group, masking: none, diagnostic
Enrollment62 (Actual)
SponsorSamsung Medical Center (Other)
ConditionsFocal Nodular Hyperplasia
InterventionsSonazoid, Superb-Microvascular imaging (Drug, device)
Datesstart 2016-05-01, primary completion 2019-04-25, completion 2019-04-25, first posted 2016-04-14, last updated 2019-12-17
Locations1 site in South Korea

Related Papers Related Patents Related Grants Related Experts
AI Assistant Save
All trials for Focal Nodular Hyperplasia All trials of Sonazoid All trials of Superb-Microvascular imaging

-Summary

Focal nodular hyperplasia (FNH) in liver is the second common benign hepatic tumor. It usually shows hypervascular mass on imaging studies and it is not easy to differentiate with other hypervascular malignant tumor. For diagnosis of FNH, contrast-enhanced ultrasonography (US) has been used to detect 'spoke-wheel sign', which can be typically seen in FNH. However, temporal window of vascular phase using contrast-enhanced US (CEUS) is very short (about 10 sec) and coordination of patient's respiration during US exam is absolutely needed. Thus, the investigators will use Superb-Microvascular imaging (SMI, Toshiba, Japan) for detection of 'spoke-wheel sign' in patients with proven FNH, which enable to detect slow micro vascular flow without using CEUS.

First, to compare the detection rate of 'spoke-wheel sign' between CEUS using sonazoid (Perfluorobutane, GE healthcare) and SMI.

Second, to compare the accuracy of size measurement between gray-scale US and SMI (reference standard: CEUS using sonazoid.)

Expand all sections  ·  Collapse all

+Detailed description

1. To evaluate the detection rate of 'spoke-wheel sign' on CEUS using sonazoid and SMI (primary outcome).

Each US findings during exam for patients with FNH were recorded by radiologist. The results were interpreted by consensus using 4 scale bar.

0\. Absence of 'spoke-wheel sign'
1. Mild suspicious of 'spoke-wheel sign'
2. Highly suspicious of 'spoke-wheel sign'
3. Definite "spoke-wheel sign'
2. To evaluated the accuracy of size measurement for FNH on gray-scale US and SMI (reference standard: CEUS using sonazoid).

To calculate the measurement error between each method and CEUS using sonazoid on US images using measurement of maximum diameter of tumor.
3. Sample size calculation according to the primary outcome.

Expecting the detection rate of "spoke-wheel sign" on SMI, 20% (known detection rate on CEUS using sonazoid, 23.5%), a sample size of 62 patients was required using 95% confidence interval.

+Arms and interventions

ArmTypeInterventionsDescription
SMI and sonazoid (single arm)ExperimentalDrug: Sonazoid; Device: Superb-Microvascular imagingPatients with focal nodular hyperplasia will undergo ultrasonography with Superb-Microvascular imaging and additional sonazoid-enhanced ultrasonography. SMI is a software function in a Toshiba Aplio 500 system. Sonazoid is contrast-material for US and it is a intervention for patient with FNH. Sonazoid will be administered at a dose of 0.015 mL/kg by manual bolus injection, followed by a 10 mL normal saline flush via a peripheral venous line
  • Sonazoid (Drug), also known as Perfluorobutane: Sonazoid: Commercially available contrast material for ultrasonography
  • Superb-Microvascular imaging (Device): Superb-Microvascular imaging: new sonographic software technique on ultrasonography to detect low-vascular flow without use of contrast media for ultrasonography

+Outcome measures

Primary outcomes

  • Grading of spoke-wheel sign on CEUS using sonazoid and SMI in patients with focal nodular hyperplasia [1 day]: a.To evaluate the detection rate of 'spoke-wheel sign' on CEUS using sonazoid and SMI (primary outcome). Each US findings during exam for patients with FNH were recorded by radiologist. The results were interpreted by consensus using 4 scale bar. 0\. Absence of 'spoke-wheel sign' 1. Mild suspicious of 'spoke-wheel sign' 2. Highly suspicious of 'spoke-wheel sign' 3. Definite "spoke-wheel sign'

Secondary outcomes

  • Measurement error of focal nodular hyperplasia between b-mode US and SMI according to the reference standard, CEUS [1 day]: To calculate the measurement error between b-mode US and SMI using measurement of maximum diameter of tumor. Reference standard is the size of tumor on sonazoid enhanced US.

+Eligibility

Sex: All, ages: 20 Years to 70 Years

Inclusion Criteria:

1\. Patients with biopsy or imaging proven focal nodular hyperplasia

Exclusion Criteria:

1. Pregnant women
2. Patient's age > 70
3. Egg allergy
4. Breast-feeding women

+Locations (1)

FacilityCityCountryStatus
Samsung Medical CenterSeoulSouth Korea

+Investigators

My Notes