Prediction of Volume Responsiveness in Presence of Left Ventricular Diastolic Dysfunction

NCT02441621 — Not applicable, Unknown, 50 participants, University Hospital Schleswig-Holstein

ClinicalTrials Daily  ·  Areas  ·  Conditions  ·  Drugs  ·  Sponsors  ·  

Prediction of Fluid Responsiveness in Presence of Diastolic Dysfunction

RegistryNCT02441621
StatusUnknown
PhaseNot applicable
Study typeInterventional; non randomized, single group, masking: none, diagnostic
Enrollment50 (Estimated)
SponsorUniversity Hospital Schleswig-Holstein (Other)
ConditionsHemodynamics
Interventionspassive leg raising, premedication, intubation and mechanical ventilation, central venous catheter, arterial catheter, transesophageal echocardiography, transpulmonary thermodilution catheter (Other)
Datesstart 2015-06-01, primary completion 2016-05-01 (estimated), completion 2016-06-01 (estimated), first posted 2015-05-12, last updated 2015-05-12
Locations1 site in Germany

Related Papers Related Patents Related Grants Related Experts
All trials for Hemodynamics All trials of passive leg raising All trials of premedication

-Summary

The ability of the global end-diastolic volume index (GEDVI), stroke volume variation (SVV) and pulse pressure variation (PPV) for prediction of fluid responsiveness in presence of left ventricular diastolic dysfunction is still unknown. The aim of the present study was to challenge the predictive power of GEDVI, SVV and PPV in cardiac surgery patients undergoing aortic valve replacement.

Expand all sections  ·  Collapse all

+Detailed description

All patients receive premedication with midazolam 7.5 mg p.o.. After induction of anesthesia with sufentanil (0.5 µg/kg) and propofol (1.5 mg/kg), orotracheal intubation is facilitated with rocuronium (0.6 mg/kg). Anesthesia is maintained with sufentanil (1 µg/kg/h) and propofol (3 mg/kg/h) and patients are ventilated with an oxygen/air mixture in volume-controlled mode, using a tidal volume of 8 ml/kg related to the ideal body weight. Positive end-expiratory pressure is set at 5 cmH2O. Continuous monitoring is performed including electrocardiogram, radial arterial pressure catheter and a central venous catheter in the right or left internal jugular vein. Before placement of a transpulmonary thermodilution catheter a transesophageal echocardiography (TOE) is performed. TOE is used to detect diastolic dysfunction of the left ventricle and to exclude right ventricular dysfunction. In presence of left ventricular dysfunction a transpulmonary thermodilution catheter is placed in the femoral artery and connected to a PiCCO2 monitor (PiCCO2, Pulsion Medical Systems, Munich, Germany). Additionally capnography, urine output, temperature (blood, bladder and nasopharyngeal), airway pressure, and pulse oximetry are recorded.

Before starting operation a passive leg raising is performed. The passive leg raising maneuver (PLR) involves a leg elevation up to 45° with the trunk in a horizontal position and was performed to induce hemodynamic effects by a volume challenge, turning unstressed blood volume to stressed volume proportional to body size. In case of an increase of stroke volume index (SVI) >15% during PLR, patients were defined as responders.

All patients were studied with no changes in anesthesia management. Measurements of SVI, GEDVI, SVV and PPV are performed before, during and after PLR. Thereafter, patients receive a fluid Bolus of 500 ml crystalloids. Again, measurements are performed before and after fluid replacement.

+Arms and interventions

ArmTypeInterventionsDescription
Passive leg raisingOtherOther: passive leg raising
premedicationOtherOther: premedication
intubation and mechanical ventilationOtherOther: intubation and mechanical ventilation
central venous catheterOtherOther: central venous catheter
arterial catheterOtherOther: arterial catheterContinuous monitoring is performed including electrocardiogram, radial arterial pressure catheter
transesophageal echocardiographyOtherOther: transesophageal echocardiography
transpulmonary thermodilution catheterOtherOther: transpulmonary thermodilution catheter
  • passive leg raising (Other): The passive leg raising maneuver (PLR) involves a leg elevation up to 45° with the trunk in a horizontal position and is performed to induce hemodynamic effects by a volume challenge, turning unstressed blood volume to stressed volume proportional to body size.
  • premedication (Other): patients receive premedication with midazolam 7.5 mg p.o.
  • intubation and mechanical ventilation (Other): After induction of anesthesia with sufentanil (0.5 µg/kg) and propofol (1.5 mg/kg), orotracheal intubation is facilitated with rocuronium (0.6 mg/kg). Anesthesia is maintained with sufentanil (1 µg/kg/h) and propofol (3 mg/kg/h) and patients are ventilated with an oxygen/air mixture in volume-controlled mode, using a tidal volume of 8 ml/kg related to the ideal body weight. Positive end-expiratory pressure is set at 5 cmH2O.
  • central venous catheter (Other): a central venous catheter in the right or left internal jugular vein.
  • arterial catheter (Other): Continuous monitoring is performed including electrocardiogram, radial arterial pressure catheter
  • transesophageal echocardiography (Other): Before placement of a transpulmonary thermodilution catheter a transesophageal echocardiography (TOE) is performed. TOE is used to detect diastolic dysfunction of the left ventricle and to exclude right ventricular dysfunction.
  • transpulmonary thermodilution catheter (Other): In presence of left ventricular dysfunction a transpulmonary thermodilution catheter is placed in the femoral artery and connected to a PiCCO2 monitor (PiCCO2, Pulsion Medical Systems, Munich, Germany).

+Outcome measures

Primary outcomes

  • Increase in stroke volume index (SVI) >15% [Patients will be obtained until the end of the operation, an expected average of 5 hours]: In presence of an increase of SVI >15% during PLR and/or 500 ml crystalloids, patients are defined as responders.

+Eligibility

Sex: All, ages: 18 Years to any

Inclusion Criteria:

* Patients > 18 yrs of age
* Patients with a left ventricular ejection fraction ≥0.5
* Patients with left ventricular diastolic dysfunction.

Exclusion Criteria:

* Emergency procedures
* Right ventricular dysfunction
* Hemodynamic instability requiring pharmacologic Support
* Ongoing arrhythmia
* Intracardiac Shunts
* Severe mitral stenosis or insufficiency
* Aortic aneurysm > 4 cm
* Use of an artificial left ventricular assist device or intra - aortic balloon pump.

+Locations (1)

FacilityCityCountryStatus
Ole BrochKiel, Schleswig-HolsteinGermany

+Publications

  • Rex S, Schalte G, Schroth S, de Waal EE, Metzelder S, Overbeck Y, Rossaint R, Buhre W. Limitations of arterial pulse pressure variation and left ventricular stroke volume variation in estimating cardiac pre-load during open heart surgery. Acta Anaesthesiol Scand. 2007 Oct;51(9):1258-67. doi: 10.1111/j.1399-6576.2007.01423.x. Epub 2007 Aug 20. PMID 17714575
  • Hofer CK, Muller SM, Furrer L, Klaghofer R, Genoni M, Zollinger A. Stroke volume and pulse pressure variation for prediction of fluid responsiveness in patients undergoing off-pump coronary artery bypass grafting. Chest. 2005 Aug;128(2):848-54. doi: 10.1378/chest.128.2.848. PMID 16100177
  • Marik PE, Cavallazzi R, Vasu T, Hirani A. Dynamic changes in arterial waveform derived variables and fluid responsiveness in mechanically ventilated patients: a systematic review of the literature. Crit Care Med. 2009 Sep;37(9):2642-7. doi: 10.1097/CCM.0b013e3181a590da. PMID 19602972
  • Renner J, Gruenewald M, Brand P, Steinfath M, Scholz J, Lutter G, Bein B. Global end-diastolic volume as a variable of fluid responsiveness during acute changing loading conditions. J Cardiothorac Vasc Anesth. 2007 Oct;21(5):650-4. doi: 10.1053/j.jvca.2007.05.006. Epub 2007 Jul 16. PMID 17905268
  • Monnet X, Rienzo M, Osman D, Anguel N, Richard C, Pinsky MR, Teboul JL. Passive leg raising predicts fluid responsiveness in the critically ill. Crit Care Med. 2006 May;34(5):1402-7. doi: 10.1097/01.CCM.0000215453.11735.06. PMID 16540963
  • Osman D, Ridel C, Ray P, Monnet X, Anguel N, Richard C, Teboul JL. Cardiac filling pressures are not appropriate to predict hemodynamic response to volume challenge. Crit Care Med. 2007 Jan;35(1):64-8. doi: 10.1097/01.CCM.0000249851.94101.4F. PMID 17080001
  • Mahjoub Y, Pila C, Friggeri A, Zogheib E, Lobjoie E, Tinturier F, Galy C, Slama M, Dupont H. Assessing fluid responsiveness in critically ill patients: False-positive pulse pressure variation is detected by Doppler echocardiographic evaluation of the right ventricle. Crit Care Med. 2009 Sep;37(9):2570-5. doi: 10.1097/CCM.0b013e3181a380a3. PMID 19623051
  • Cioffi G, Mazzone C, Barbati G, Rossi A, Nistri S, Ognibeni F, Tarantini L, Di Lenarda A, Faggiano P, Pulignano G, Stefenelli C, de Simone G, Devereux RB. Combined circumferential and longitudinal left ventricular systolic dysfunction in patients with asymptomatic aortic stenosis. Echocardiography. 2015 Jul;32(7):1064-72. doi: 10.1111/echo.12825. Epub 2014 Nov 5. PMID 25370995
  • Rader F, Sachdev E, Arsanjani R, Siegel RJ. Left ventricular hypertrophy in valvular aortic stenosis: mechanisms and clinical implications. Am J Med. 2015 Apr;128(4):344-52. doi: 10.1016/j.amjmed.2014.10.054. Epub 2014 Nov 25. PMID 25460869

+Investigators