A Clinical Study of a Spine Fusion System in Vertebral Body Fusion Surgery

NCT02252185 — Not applicable, Completed, 106 participants, Johnson & Johnson Medical (Suzhou) Ltd.

ClinicalTrials Daily  ·  Areas  ·  Conditions  ·  Drugs  ·  Sponsors  ·  

A Prospective, Multicenter, Randomized, Open-label, Controlled Study to Evaluate the Safety and Efficacy of a Spine Fusion System in Vertebral Body Fusion Surgery

RegistryNCT02252185
StatusCompleted
PhaseNot applicable
Study typeInterventional; randomized, parallel, masking: none, treatment
Enrollment106 (Actual)
SponsorJohnson & Johnson Medical (Suzhou) Ltd. (Industry)
ConditionsDisc Degenerative Disease, Spondylolisthesis, Spinal Fracture, Spinal Deformity, Spinal Stenosis, Spinal Tumor
InterventionsJohnson&Johnson Medical Suzhou made Spine Fusion System, Imported EXPEDIUM screws and OPAL cage (Device)
Datesstart 2014-07-01, primary completion 2015-09-01, completion 2015-12-01, first posted 2014-09-30, last updated 2015-12-03
Locations8 sites in China

Related Papers Related Patents Related Grants Related Experts
All trials for Disc Degenerative Disease All trials for Spondylolisthesis All trials of Johnson&Johnson Medical Suzhou made Spine Fusion System All trials of Imported EXPEDIUM screws and OPAL cage

-Summary

The primary objective of this study is to demonstrate that the efficacy and safety of Spine fusion system manufactured in China is no inferior than imported product.

Expand all sections  ·  Collapse all

+Detailed description

This study is a prospective, multicenter, randomized, comparative, non-inferiority study comparing the change of Japanese Orthopaedic Association Score from baseline at postoperative 24 weeks for patients implanted with local made Spine Fusion System versus imported products.

+Arms and interventions

ArmTypeInterventionsDescription
China made spine fusion systemExperimentalDevice: Johnson&Johnson Medical Suzhou made Spine Fusion Systempatents in this arm will be implanted with Johnson\&Johnson Medical Suzhou made Spine Fusion System.
Imported spine fusion systemActive comparatorDevice: Imported EXPEDIUM screws and OPAL cagepatents in this arm will be implanted with Imported EXPEDIUM screws and OPAL cage .
  • Johnson&Johnson Medical Suzhou made Spine Fusion System (Device): interventional device is Spine Fusion System that is manufactured by Johnson \& Johnson Medical Suzhou Ltd.
  • Imported EXPEDIUM screws and OPAL cage (Device): Comparator in this study is active comparator.

+Outcome measures

Primary outcomes

  • Change of Japanese Orthopaedic Association score [Preoperation and 24week post operation]: Questionnaire

Secondary outcomes

  • Improvement rate of Japanese Orthopaedic Association score [7day, 12week, and 24week post operation]: Questionnaire
  • Fixation stability [12week, and 24week post operation]: Fixation stability should be measured based on translational motion and angular motion which is demonstrated on X-Ray examination (A/P lateral, Flexion and extension).
  • Visual Analogue Score of low back and leg pain [7day, 12week, and 24week post operation]: Visual Analogue Scale
  • Wound healing [7day, 12week, and 24week post operation]: would healing are classified as 3 classes. (Class I, Class II, Class III)

Other outcomes

  • Adverse Events [up to 24week post operation]: Number of events

+Eligibility

Sex: All, ages: 20 Years to 70 Years, accepts healthy volunteers

Inclusion Criteria:

* 20-70 years old, male or female;
* Subject being diagnosed as having disc degeneration disease, spondylolisthesis, spinal fracture, deformity(degenerative deformity), spinal stenosis, or spinal tumor, has been treated with conservative treatment without relief or getting worse, who is suitable for surgery according to clinic practice.
* Subject is a suitable candidate for implanting investigational products described in study protocols according to investigator's assessment;
* Patient, in the opinion of the Clinical Investigator, is able to understand this clinical investigation and willing to be available for each required study procedure over the study duration.
* Subject has been given voluntary, written informed consent to participate in this clinical investigation and has authorized the transfer of his/her information to study Sponsor.

Exclusion Criteria:

* Patient has a local or systemic infection.
* Patient has had one or more previous non-fusion spinal surgery at the involved level(s).
* Patient without spinal deformity and requires fusion at 3 or more levels.
* Has been previously diagnosed with osteopenia, osteoporosis, or osteomalacia to a degree that spinal instrumentation would be contraindicated
* Has presence of active malignancy
* Has a medical condition with less than 1 year of life expectancy.
* Pregnancy or women in lactation period.
* Is grossly obese, i.e. Body Mass Index≥40.
* Has a diagnosis, which requires postoperative medication or treatment that interferes with fusion, such as steroids, chemotherapy, radiotherapy, growth factor (for more than 3 months), Nonsteroidal Antiinflammatory Drugs(for more than 3 months), and etc.
* Has history of endocrine or metabolic disorder known to affect osteogenesis (e.g. uncontrolled Diabetes with medication, renal osteodystrophy, or osteogenesis imperfect)
* Alcoholic (taking more than 40g/day, equals to 100ml 50°Chinese liquor), smoking more than 40 cigarettes/day, or Drug abuser;
* Is currently participating in another investigational drug or device study.

+Locations (8)

FacilityCityCountryStatus
Anhui Province HospitalHefei, AnhuiChina
Beijing Jishuitan HospitalBeijing, Beijing MunicipalityChina
Henan Provincial People's HospitalZhengzhou, HenanChina
Jiangxi Provincial People's HospitalNanchang, JiangxiChina
Shanghai Ruijin HospitalShanghai, Shanghai MunicipalityChina
Xijing HospitalXi’an, ShanxiChina
The First Affiliated Hospital of Xi'an Jiaotong University Medical CollegeXi’an, ShanxiChina
The First Affiliated Hospital of Kunming Medical CollegeKunming, YunnanChina

+Investigators

  • Wei Tian, Principal investigator, Beijing Jishuitan Hospital