Stabilometry After Pressure Release of the Flexor Digitorum Brevis Muscle Versus a Non-emission Laser.

NCT06509347 — Not applicable, Completed, 34 participants, Mayuben Private Clinic

ClinicalTrials Daily  ·  Areas  ·  Conditions  ·  Drugs  ·  Sponsors  ·  

Stabilometry After Pressure Release of the Flexor Digitorum Brevis Muscle Versus a Non-emission Laser: Clinical Trial

RegistryNCT06509347
StatusCompleted
PhaseNot applicable
Study typeInterventional; randomized, parallel, masking: single, treatment
Enrollment34 (Actual)
SponsorMayuben Private Clinic (Other)
ConditionsBalance, Manual Therapy, Foot, Myofascial Pain Syndrome, Myofascial Trigger Point
InterventionsPreassure release, Non-emision laser (Other)
Datesstart 2024-07-22, primary completion 2024-07-24, completion 2024-07-28, first posted 2024-07-19, last updated 2024-07-30
Locations1 site in Spain

Related Papers Related Patents Related Grants Related Experts
All trials for Balance All trials for Manual Therapy All trials of Preassure release All trials of Non-emision laser

-Summary

In this study we will test the effects of pressure release on the Flexor digitorum brevis muscle on stabilometric variables that support static equilibrium.

Expand all sections  ·  Collapse all

+Detailed description

In this study we will test the effects of pressure release on the Flexor digitorum brevis muscle on the stabilometric variables that support static balance. To test the effects on balance.

+Arms and interventions

ArmTypeInterventionsDescription
Pressure releaseExperimentalOther: Preassure releaseApplication of pressure on the trigger point of the flexor digitorum brevis until remission of referred pain for a minimum of 90 seconds, at least 3 cycles.
Non-emision LaserSham comparatorOther: Non-emision laserApplication of a non-emitting laser for 5 minutes on the trigger point of the flexor digitorum brevis muscle.
  • Preassure release (Other): Preassure release in Flexor digitorum brevis trigger point muscle.
  • Non-emision laser (Other): Bilateral non emission Laser in latent trigger points of the Flexor digitorum Brevis Muscle

+Outcome measures

Primary outcomes

  • 1.Stabilometric variable x displacement open eyes before pressure release. [Through study completion, an average of 1 week.]: Stabilometry assessment was used and subjects were instructed to stand barefoot on the force platform, participants were instructed to remain in a relaxed standing posture with feet shoulder-width apart and positioned at 30º away from the midline. Stabilometry variables measure displacement of the center of pressures in X (in millimeters) with open eyes.
  • 2.Stabilometric variable x displacement open eyes before non emission Laser [Through study completion, an average of 1 week.]: Stabilometry assessment was used and subjects were instructed to stand barefoot on the force platform, participants were instructed to remain in a relaxed standing posture with feet shoulder-width apart and positioned at 30º away from the midline. Stabilometric variables measure displacement of the center of pressures in Y (in millimeters) with open eyes.
  • 3.Stabilometric variable center of pressure area open eyes before pressure release. [Through study completion, an average of 1 week.]: Stabilometric assessment was used and subjects were instructed to stand barefoot on the force platform, participants were instructed to remain in a relaxed standing posture with feet shoulder-width apart and positioned at 30º away from the midline. Stabilometric variables measure displacement of the center of Pressure (COP) area (in millimeters²) with eyes open.
  • 4.Stabilometric variable center of pressure area open eyes before non emission laser. [Through study completion, an average of 1 week.]: Stabilometric assessment was used and subjects were instructed to stand barefoot on the force platform, participants were instructed to remain in a relaxed standing posture with feet shoulder-width apart and positioned at 30º away from the midline. Stabilometric variables measure displacement of the center of Pressure (COP) area (in millimeters²) with eyes open.
  • 5.Stabilometric variable center of pressure speed displacement of the anteroposterior(a-p) direction open eyes before pressure release. [Through study completion, an average of 1 week.]: Stabilometric assessment was used and subjects were instructed to stand barefoot on the force platform, participants were instructed to remain in a relaxed standing posture with feet shoulder-width apart and positioned at 30º away from the midline. Stabilometric variables measure center of pressure speed displacement of the anteroposterior(a-p) direction (in millimeters/second).
  • 6.Stabilometric variable center of pressure speed displacement of the anteroposterior(a-p) direction open eyes before pressure non-emission Laser. [Through study completion, an average of 1 week.]: Stabilometric assessment was used and subjects were instructed to stand barefoot on the force platform, participants were instructed to remain in a relaxed standing posture with feet shoulder-width apart and positioned at 30º away from the midline. Stabilometric variables measure center of pressure speed displacement of the anteroposterior(a-p) direction (in millimeters/second).
  • 7.Stabilometric variable y displacement open eyes before pressure release [Through study completion, an average of 1 week.]: Stabilometric assessment was used and subjects were instructed to stand barefoot on the force platform, participants were instructed to remain in a relaxed standing posture with feet shoulder-width apart and positioned at 30º away from the midline. Stabilometric variables measure displacement of the center of pressures in Y (in millimeters) with open eyes.
  • 8.Stabilometric variable x displacement open eyes before non emission Laser [Through study completion, an average of 1 week.]: Stabilometric assessment was used and subjects were instructed to stand barefoot on the force platform, participants were instructed to remain in a relaxed standing posture with feet shoulder-width apart and positioned at 30º away from the midline. Stabilometry variables measure displacement of the center of pressures in Y (in millimeters) with open eyes.
  • 9.Stabilometric variable center of pressure speed displacement of the latero-lateral(lat-lat) direction open eyes before pressure release [Through study completion, an average of 1 week.]: Stabilometric assessment was used and subjects were instructed to stand barefoot on the force platform, participants were instructed to remain in a relaxed standing posture with feet shoulder-width apart and positioned at 30º away from the midline. Stabilometry variables measure center of pressure speed displacement of the latero-lateral(lat-lat) direction (in millimeters/second).
  • 10.Stabilometric variable center of pressure speed displacement of the latero-lateral(lat-lat) direction open eyes non emision Laser. [Through study completion, an average of 1 week.]: Stabilometric assessment was used and subjects were instructed to stand barefoot on the force platform, participants were instructed to remain in a relaxed standing posture with feet shoulder-width apart and positioned at 30º away from the midline. Stabilometry variables measure center of pressure speed displacement of the latero-lateral(lat-lat) direction (in millimeters/second).
  • 11.Stabilometric variable x displacement closed eyes before pressure release [Through study completion, an average of 1 week.]: Stabilometric assessment was used and subjects were instructed to stand barefoot on the force platform, participants were instructed to remain in a relaxed standing posture with feet shoulder-width apart and positioned at 30º away from the midline. Stabilometric variables measure displacement of the center of pressures in X (in millimeters) with closed eyes.
  • 12.Stabilometric variable x displacement closed eyes before non emission Laser [Through study completion, an average of 1 week.]: Stabilometric assessment was used and subjects were instructed to stand barefoot on the force platform, participants were instructed to remain in a relaxed standing posture with feet shoulder-width apart and positioned at 30º away from the midline. Stabilometric variables measure displacement of the center of pressures in X (in millimeters) with closed eyes.
  • 13.Stabilometric variable center of pressure area closed eyes before pressure release. [Through study completion, an average of 1 week.]: Stabilometric assessment was used and subjects were instructed to stand barefoot on the force platform, participants were instructed to remain in a relaxed standing posture with feet shoulder-width apart and positioned at 30º away from the midline. Stabilometric variables measure displacement of the center of Pressure (COP) area (in millimeters²) with closed eyes.
  • 14.Stabilometric variable center of pressure area closed eyes before non emission laser. [Through study completion, an average of 1 week.]: Stabilometric assessment was used and subjects were instructed to stand barefoot on the force platform, participants were instructed to remain in a relaxed standing posture with feet shoulder-width apart and positioned at 30º away from the midline. Stabilometric variables measure displacement of the center of Pressure (COP) area (in millimeters²) with closed eyes.
  • 15.5.Stabilometric variable center of pressure speed displacement of the anteroposterior(a-p) direction closed eyes before pressure release. [Through study completion, an average of 1 week.]: Stabilometric assessment was used and subjects were instructed to stand barefoot on the force platform, participants were instructed to remain in a relaxed standing posture with feet shoulder-width apart and positioned at 30º away from the midline. Stabilometric variables measure center of pressure speed displacement of the anteroposterior(a-p) direction (in millimeters/second).
  • .Stabilometric variable center of pressure speed displacement of the anteroposterior(a-p) direction closed eyes before pressure non-emission Laser. [Through study completion, an average of 1 week.]: Stabilometric assessment was used and subjects were instructed to stand barefoot on the force platform, participants were instructed to remain in a relaxed standing posture with feet shoulder-width apart and positioned at 30º away from the midline. Stabilometric variables measure center of pressure speed displacement of the anteroposterior(a-p) direction (in millimeters/second).
  • 17.Stabilometric variable y displacement closed eyes before pressure release [Through study completion, an average of 1 week.]: Stabilometric assessment was used and subjects were instructed to stand barefoot on the force platform, participants were instructed to remain in a relaxed standing posture with feet shoulder-width apart and positioned at 30º away from the midline. Stabilometric variables measure displacement of the center of pressures in Y (in millimeters) with closed eyes.
  • 18.Stabilometric variable x displacement closed eyes before non emission Laser [Through study completion, an average of 1 week.]: Stabilometric assessment was used and subjects were instructed to stand barefoot on the force platform, participants were instructed to remain in a relaxed standing posture with feet shoulder-width apart and positioned at 30º away from the midline. Stabilometric variables measure displacement of the center of pressures in Y (in millimeters) with closed eyes.
  • 9.Stabilometric variable center of pressure speed displacement of the latero-lateral(lat-lat) direction closed eyes before pressure release. [Through study completion, an average of 1 week.]: Stabilometric assessment was used and subjects were instructed to stand barefoot on the force platform, participants were instructed to remain in a relaxed standing posture with feet shoulder-width apart and positioned at 30º away from the midline. Stabilometric variables measure center of pressure speed displacement of the latero-lateral(lat-lat) direction (in millimeters/second).
  • 20. Stabilometric variable center of pressure speed displacement of the latero-lateral(lat-lat) direction closed eyes non emission Laser. [Through study completion, an average of 1 week.]: Stabilometric assessment was used and subjects were instructed to stand barefoot on the force platform, participants were instructed to remain in a relaxed standing posture with feet shoulder-width apart and positioned at 30º away from the midline. Stabilometric variables measure center of pressure speed displacement of the latero-lateral(lat-lat) direction (in millimeters/second).

+Eligibility

Sex: All, ages: 18 Years to 39 Years

Inclusion Criteria:

* Healthy individuals
* Must have latent trigger point in Flexor Brevis Digitorum muscles with no other pathologies.

Exclusion Criteria:

* Previous lower extremities surgery.
* History of lower extremities injury with residual symptoms (pain, "giving-away" sensations) within the last year.
* Leg-length discrepancy more than 1 cm
* Balance deficits (determined by oral questionnaire regarding falls)

+Locations (1)

FacilityCityCountryStatus
Eva María Martínez-Jiménez In Mayuben CLinicMadridSpain

+Publications

  • Results publication: Martinez-Jimenez EM, Becerro-de-Bengoa-Vallejo R, Losa-Iglesias ME, Perez-Boal E, Posada-Ordax J, Sanchez-Serena A, Trevisson-Redondo B, Benito-de-Pedro M, Martinez-Corcoles V, Casado-Hernandez I. Plantar pressures and stabilometry effects of ischemic compression in Flexor digitorum brevis muscle Myofascial Trigger Point: A prepost study. PLoS One. 2025 Aug 14;20(8):e0329734. doi: 10.1371/journal.pone.0329734. eCollection 2025. PMID 40811690