Esophageal Temperature During PVI Using Q-DOT Micro

NCT06392932 — Not applicable, Recruiting, 30 participants, Cedars-Sinai Medical Center

ClinicalTrials Daily  ·  Areas  ·  Conditions  ·  Drugs  ·  Sponsors  ·  

Esophageal Temperature Dynamics and Injury During Pulmonary Vein Isolation With Temperature Controlled Very-High-Power Short-Duration Lesions Using the Novel Q-DOT Micro Ablation Catheter

RegistryNCT06392932
StatusRecruiting
PhaseNot applicable
Study typeInterventional; randomized, parallel, masking: single, treatment
Enrollment30 (Estimated)
SponsorCedars-Sinai Medical Center (Other); collaborators: Biosense Webster, Inc.
ConditionsAtrial Fibrillation Paroxysmal
InterventionsQDOT Micro ablation catheter, ST SF ablation catheter (Device)
Datesstart 2024-10-04, primary completion 2026-10-01 (estimated), completion 2027-03-01 (estimated), first posted 2024-05-01, last updated 2025-10-28
Locations1 site in United States

Related Papers Related Patents Related Grants Related Experts
All trials for Atrial Fibrillation Paroxysmal All trials of QDOT Micro ablation catheter All trials of ST SF ablation catheter

-Summary

This study will assess how two different ablation strategies, using two different ablation catheters during catheter ablation for paroxysmal atrial fibrillation, affect the temperature of the esophagus during ablation, and the risk of injury to the esophagus.

Expand all sections  ·  Collapse all

+Detailed description

This is a prospective randomized controlled trial, studying patients undergoing ablation involving pulmonary vein isolation for paroxysmal atrial fibrillation. Patients will be assigned to undergo conventional high-power short-duration ablation or temperature-controlled very-high-power short-duration ablation, and esophageal outcomes including temperature changes during ablation and esophageal injury as assessed by post-procedure capsule endoscopy will be compared between the groups. The hypothesis is that very-high-power short-duration ablation will lead to lower rises in esophageal temperature and lower rates of esophageal findings during capsule endoscopy.

+Arms and interventions

ArmTypeInterventionsDescription
QDOT ArmExperimentalDevice: QDOT Micro ablation catheterTemperature-controlled very-high-power short-duration ablation using the QDOT Micro catheter.
ST SF ArmActive comparatorDevice: ST SF ablation catheterConventional high-power short-duration ablation using the ThermoCool ST SF catheter.
  • QDOT Micro ablation catheter (Device): QDOT Micro ablation catheter
  • ST SF ablation catheter (Device): ST SF ablation catheter

+Outcome measures

Primary outcomes

  • Maximal change in esophageal temperature during posterior wall isolation. [During ablation procedure.]

Secondary outcomes

  • Presence of esophageal thermal injury seen on post-procedure capsule endoscopy. [2-4 days after ablation procedure.]
  • Presence of procedural complications. [During and immediately following ablation procedure.]

Other outcomes

  • Number of RF ablation lesions to performed pulmonary vein isolation. [During ablation procedure.]
  • RF time during pulmonary vein isolation. [During ablation procedure.]
  • Left atrial dwell time to achieve pulmonary vein isolation. [During ablation procedure.]
  • Achievement of first pass pulmonary vein isolation. [During ablation procedure.]

+Eligibility

Sex: All, ages: 18 Years to any

Inclusion Criteria:

1. Provision of signed and dated informed consent form
2. Stated willingness to comply with all study procedures and availability for the duration of the study
3. Male or female, aged greater than or equal to 18 years
4. Diagnosed with paroxysmal atrial fibrillation
5. Undergoing RF catheter ablation for treatment of paroxysmal atrial fibrillation that will involve circumferential point-by-point radiofrequency ablation pulmonary vein isolation with no additional left atrial posterior wall ablation planned

Exclusion Criteria:

1. Patients who have undergone prior left atrial ablation procedures.
2. Patients where the use of the Q-DOT Micro ablation catheter in QMODE+ (i.e. temperature-controlled very-high-power short-duration ablation) is felt to be unsafe.
3. Patients who have contraindications to capsule endoscopy, or GI conditions that may increase the risks of capsule endoscopy (e.g. esophageal strictures, inflammatory bowel disease, etc)
4. Any records flagged "break the glass" or "research opt out."

+Locations (1)

FacilityCityCountryStatus
Cedars-Sinai Smidt Heart InstituteLos Angeles, CaliforniaUnited StatesRecruiting