Comparison of Allegra vs Sapien Transcatheter Aortic Valves in Valve-In-Valve Indication

NCT06049654 — Not applicable, Recruiting, 104 participants, Fundación EPIC

ClinicalTrials Daily  ·  Areas  ·  Conditions  ·  Drugs  ·  Sponsors  ·  

Clinical Trial of the Results of Allegra vs Sapien Transcatheter Aortic Valves in Valve-In-Valve Indication

RegistryNCT06049654
StatusRecruiting
PhaseNot applicable
Study typeInterventional; randomized, parallel, masking: none, treatment
Enrollment104 (Estimated)
SponsorFundación EPIC (Other)
ConditionsAortic Valve Stenosis, Structural Valve Deterioration
InterventionsNVT ALLEGRA TAVI System TF, EDWARDS SAPIEN 3 or SAPIEN ULTRA SYSTEM (Device)
Datesstart 2024-02-01, primary completion 2027-11-01 (estimated), completion 2027-11-01 (estimated), first posted 2023-09-22, last updated 2026-09-24
Locations12 sites in Italy, Spain, United Kingdom

Related Papers Related Patents Related Grants Related Experts
All trials for Aortic Valve Stenosis All trials for Structural Valve Deterioration All trials of NVT ALLEGRA TAVI System TF All trials of EDWARDS SAPIEN 3 or SAPIEN ULTRA SYSTEM

-Summary

The VIVALL-2 study is a randomized trial to compare the self-expandable supra-annular Allegra and the balloon-expandable intra-annular Edwards transcatheter valve systems in patients with degenerated biological aortic surgical valve.

Expand all sections  ·  Collapse all

+Detailed description

In the VIVALL.2 study, 104 patients with severely degenerated biological aortic surgical valve accepted for vave-in-valve procedure (transcatheter aortic valve implantation) will be randomized to be treated with the self-expandable supra-annular Allegra or the balloon-expandable intra-annular Edwards systems. The primary end-point will be trans-aortic mean gradient determined by trans-thoracic echocardiography at 30 days. The proportion of patients with moderate or severe prosthesis mismatch at 30 days will be a secondary end-.point. Different countries will participate in the study.

+Arms and interventions

ArmTypeInterventionsDescription
NVT ALLEGRA System TFActive comparatorDevice: NVT ALLEGRA TAVI System TFNVT ALLEGRA System TF
EDWARDS SAPIEN 3 or SAPIEN ULTRA SYSTEMExperimentalDevice: EDWARDS SAPIEN 3 or SAPIEN ULTRA SYSTEMEDWARDS SAPIEN 3 or SAPIEN ULTRA SYSTEM
  • NVT ALLEGRA TAVI System TF (Device): Transcatheter aortic valve implantation of a NVT ALLEGRA TAVI System TF in patients with severe haemodynamical valve deterioration of a biological aortic valve implanted surgically
  • EDWARDS SAPIEN 3 or SAPIEN ULTRA SYSTEM (Device): Transcatheter aortic valve implantation of an EDWARDS SAPIEN 3 SYSTEM in patients with severe haemodynamical valve deterioration of a biological aortic valve implanted surgically

+Outcome measures

Primary outcomes

  • Trans-aortic mean gradient after Valve-in-Valve procedure, measured by transthoracic echocardiography (TTE). [30 days]: Trans-aortic mean gradient after Valve-in-Valve procedure, measured by transthoracic echocardiography (TTE).

Secondary outcomes

  • Proportion of patients with device success after the Valve In Valve (VIV) procedure [30 days]: Device success after the VIV procedure to the VARC-3 criteria
  • Proportion of patients with a trans-aortic mean gradient higher than 20 mmHg after the VIV procedure [30 days]: Proportion of patients with a trans-aortic mean gradient higher than 20 mmHg after the VIV procedure
  • Proportion of patients with moderate or severe prosthesis mismatch 30 days after the VIV intervention. [30 days]: Proportion of patients with moderate or severe prosthesis mismatch 30 days after the VIV intervention.
  • Early safety at 30 days as defined by Valve Academic Research Consortium 3 (VARC-3) criteria [30 days]: freedom from: all-cause mortality, all stroke, VARC type 2-4 bleeding, major vascular, access-related, or cardiac structural complication, acute kidney injury stage 3 or 4, moderate or severe aortic regurgitation, new permanent pacemaker due to procedure related conduction abnormalities, surgery or intervention related to the device.
  • Clinical efficacy at 1 year as defined by VARC-3 criteria [1 year]: freedom from: all-cause mortality, all stroke, hospitalization for procedure- or valve related causes, KCCQ Overall Summary Score <45 or decline from baseline of >10 point.
  • Trans-aortic mean gradient [1 year]: Trans-aortic mean gradient 1 year after TAVR procedure
  • Death [1 year]: Incidence of Death
  • Stroke [1 year]: Incidence of Stroke

+Eligibility

Sex: All, ages: 18 Years to any

Inclusion Criteria:

Patients meeting ALL the following criteria will be included:

* Patients aged ≥ 18 years.
* Severe haemodynamical valve deterioration of a biological aortic valve implanted surgically, including severe valve stenosis (effective aortic valve area < 1.0 cm2) and/or severe valve regurgitation.
* The patient has cardiac symptoms and/or deterioration of left ventricular ejection fraction attributable to the aortic valve disease.
* Heart team decision of VIV procedure.
* Patient is willing to return at 30 days for TTE and to be clinically contacted at 1 year.

Exclusion Criteria:

Patients meeting, at least, 1 of the following criteria will be excluded:

* Patients who openly express their refusal to participate in the study.
* Female patients in gestational age.
* Presence or suspicious of biological aortic valve thrombosis.
* Known hypersensitivity or contraindication to antithrombotic therapy (or inability to be anticoagulated during the procedure), nitinol, or sensitivity to contrast media which cannot be adequately pre-medicated.
* Ongoing sepsis and/or suspicious or diagnosis of endocarditis.
* Patients whose life expectancy is < 1 year due to non-cardiac comorbid conditions.
* Medical, social, or psychological conditions that preclude the subject from appropriate consent or adherence to the protocol required follow-up exams.
* True inner diameter of the prosthetic valve > 27 mm.
* Transfemoral access inadequate to accommodate an 18F sheath.
* Patients included in other clinical trials (excluding registries).

+Locations (12)

FacilityCityCountryStatus
Azienda Ospedaliero- Universitaria di AlessandriaAlessandriaItalyRecruiting
ASST Spedali Civili di BresciaBresciaItalyRecruiting
Azienda Ospedaliera di PerugiaPerugiaItalyRecruiting
Hospital Universitari de BellvitgeL'Hospitalet de LlobregatSpainRecruiting
Hospital Clinico San CarlosMadridSpainRecruiting
Hospital Universitario de La PazMadridSpainRecruiting
Hospital Universitario Puerta De HierroMajadahondaSpainRecruiting
Hospital Clínico Universitario de SalamancaSalamancaSpainRecruiting
Hospital Universitari I Politècnic de La FeValenciaSpainRecruiting
Manchester University NHS Foundation TrustManchesterUnited KingdomRecruiting
Freeman HospitalNewcastleUnited KingdomRecruiting
Morriston Hospital, SwanseaSwanseaUnited KingdomRecruiting

+Publications

  • Moreno R, Baz JA, Moreu J, Berenguer A, Gonzalvez-Garcia A, Galeote G, Hernandez U, Canton T, Jimenez-Valero S, Jurado-Roman A, Moya H, Lazaro E. Transcatheter aortic valve implantation for degenerated aortic valves: Experience with a new supra-annular device. The Spanish Allegra valve-in-valve (SAVIV) registry. Catheter Cardiovasc Interv. 2021 Aug 1;98(2):365-370. doi: 10.1002/ccd.29742. Epub 2021 Apr 23. PMID 33890713
  • Hirji SA, Percy ED, Zogg CK, Malarczyk A, Harloff MT, Yazdchi F, Kaneko T. Comparison of in-hospital outcomes and readmissions for valve-in-valve transcatheter aortic valve replacement vs. reoperative surgical aortic valve replacement: a contemporary assessment of real-world outcomes. Eur Heart J. 2020 Aug 1;41(29):2747-2755. doi: 10.1093/eurheartj/ehaa252. PMID 32445575
  • Bleiziffer S, Simonato M, Webb JG, Rodes-Cabau J, Pibarot P, Kornowski R, Windecker S, Erlebach M, Duncan A, Seiffert M, Unbehaun A, Frerker C, Conzelmann L, Wijeysundera H, Kim WK, Montorfano M, Latib A, Tchetche D, Allali A, Abdel-Wahab M, Orvin K, Stortecky S, Nissen H, Holzamer A, Urena M, Testa L, Agrifoglio M, Whisenant B, Sathananthan J, Napodano M, Landi A, Fiorina C, Zittermann A, Veulemans V, Sinning JM, Saia F, Brecker S, Presbitero P, De Backer O, Sondergaard L, Bruschi G, Franco LN, Petronio AS, Barbanti M, Cerillo A, Spargias K, Schofer J, Cohen M, Munoz-Garcia A, Finkelstein A, Adam M, Serra V, Teles RC, Champagnac D, Iadanza A, Chodor P, Eggebrecht H, Welsh R, Caixeta A, Salizzoni S, Dager A, Auffret V, Cheema A, Ubben T, Ancona M, Rudolph T, Gummert J, Tseng E, Noble S, Bunc M, Roberts D, Kass M, Gupta A, Leon MB, Dvir D. Long-term outcomes after transcatheter aortic valve implantation in failed bioprosthetic valves. Eur Heart J. 2020 Aug 1;41(29):2731-2742. doi: 10.1093/eurheartj/ehaa544. PMID 32592401
  • Rodes-Cabau J, Abbas AE, Serra V, Vilalta V, Nombela-Franco L, Regueiro A, Al-Azizi KM, Iskander A, Conradi L, Forcillo J, Lilly S, Calabuig A, Fernandez-Nofrerias E, Mohammadi S, Panagides V, Pelletier-Beaumont E, Pibarot P. Balloon- vs Self-Expanding Valve Systems for Failed Small Surgical Aortic Valve Bioprostheses. J Am Coll Cardiol. 2022 Aug 16;80(7):681-693. doi: 10.1016/j.jacc.2022.05.005. Epub 2022 May 18. PMID 35597385
  • Hahn RT, Webb J, Pibarot P, Ternacle J, Herrmann HC, Suri RM, Dvir D, Leipsic J, Blanke P, Jaber WA, Kodali S, Kapadia S, Makkar R, Thourani V, Williams M, Salaun E, Vincent F, Xu K, Leon MB, Mack M. 5-Year Follow-Up From the PARTNER 2 Aortic Valve-in-Valve Registry for Degenerated Aortic Surgical Bioprostheses. JACC Cardiovasc Interv. 2022 Apr 11;15(7):698-708. doi: 10.1016/j.jcin.2022.02.014. PMID 35393102
  • Sa MPBO, Van den Eynde J, Simonato M, Cavalcanti LRP, Doulamis IP, Weixler V, Kampaktsis PN, Gallo M, Laforgia PL, Zhigalov K, Ruhparwar A, Weymann A, Pibarot P, Clavel MA. Valve-in-Valve Transcatheter Aortic Valve Replacement Versus Redo Surgical Aortic Valve Replacement: An Updated Meta-Analysis. JACC Cardiovasc Interv. 2021 Jan 25;14(2):211-220. doi: 10.1016/j.jcin.2020.10.020. PMID 33478639
  • Landes U, Sathananthan J, Witberg G, De Backer O, Sondergaard L, Abdel-Wahab M, Holzhey D, Kim WK, Hamm C, Buzzatti N, Montorfano M, Ludwig S, Conradi L, Seiffert M, Guerrero M, El Sabbagh A, Rodes-Cabau J, Guimaraes L, Codner P, Okuno T, Pilgrim T, Fiorina C, Colombo A, Mangieri A, Eltchaninoff H, Nombela-Franco L, Van Wiechen MPH, Van Mieghem NM, Tchetche D, Schoels WH, Kullmer M, Tamburino C, Sinning JM, Al-Kassou B, Perlman GY, Danenberg H, Ielasi A, Fraccaro C, Tarantini G, De Marco F, Redwood SR, Lisko JC, Babaliaros VC, Laine M, Nerla R, Castriota F, Finkelstein A, Loewenstein I, Eitan A, Jaffe R, Ruile P, Neumann FJ, Piazza N, Alosaimi H, Sievert H, Sievert K, Russo M, Andreas M, Bunc M, Latib A, Godfrey R, Hildick-Smith D, Chuang MA, Blanke P, Leipsic J, Wood DA, Nazif TM, Kodali S, Barbanti M, Kornowski R, Leon MB, Webb JG. Transcatheter Replacement of Transcatheter Versus Surgically Implanted Aortic Valve Bioprostheses. J Am Coll Cardiol. 2021 Jan 5;77(1):1-14. doi: 10.1016/j.jacc.2020.10.053. PMID 33413929