Visual Performance of Multifocal Intraocular Lenses

NCT04913792 — Unknown, 30 participants, Wenzhou Medical University

ClinicalTrials Daily  ·  Areas  ·  Conditions  ·  Drugs  ·  Sponsors  ·  

Clinical Outcomes With an Extended Range of Vision Intraocular Lens

RegistryNCT04913792
StatusUnknown
Study typeObservational
Enrollment30 (Estimated)
SponsorWenzhou Medical University (Other)
ConditionsIOL, Cataract
InterventionsZXR00 (Device)
Datesstart 2016-11-01, primary completion 2021-07-07 (estimated), completion 2021-12-01 (estimated), first posted 2021-06-04, last updated 2021-06-04
Locations1 site in China

Related Papers Related Patents Related Grants Related Experts
All trials for IOL All trials for Cataract All trials of ZXR00

-Summary

To evaluate the clinical outcomes with an extended range of vision (ERV) IOL based on achromatic diffractive technology.

Expand all sections  ·  Collapse all

+Detailed description

This was a prospective comparative study including 60 eyes undergoing cataract surgery with implantation of the ERV Tecnis Symfony IOL (Abbott Medical Optics, Inc.) (ERV group: 60 eyes of 30 patients). Visual, refractive, contrast sensitivity, defocus curve, ocular optical quality (Optical Quality Analysis System; iTrace), and visual function questionair(NEI-VFQ 25) outcomes were evaluated during a 3-month follow-up.

+Arms and interventions

ArmTypeInterventionsDescription
ZXR00Device: ZXR00The ZXR00 group included 30 patients bilaterally implanted with the Tecnis Symfony IOL (Abbott Medical Optics, Inc.)
  • ZXR00 (Device): This prospective comparative study included 60 eyes undergoing cataract surgery with implantation of an extended range of vision IOL.(Abbott Medical Optics, Inc.)

+Outcome measures

Primary outcomes

  • Uncorrected distance VA(5m,66cm,40cm) [After operation (Month 3)]: logarithmic visual acuity chart

Secondary outcomes

  • Questionnaire concerning halo and visual function [After operation (Month 3)]: NEI-VFQ 25 patient questionnaire score. The questionnaire consisted of 3 parts. The first part assessed patients' satisfaction with their overall vision during the day, or at night. The score ranged from 1 to 5 (1 = not at all; 2 = a little bit; 3 = moderately; 4 = quite a bit; 5 = extremely). In part 2, patients were asked to rate the extent to which they have difficulties with their overall vision during the day or at night. The score ranged from 1 to 5 (1 = none of the time; 2 = some of the time; 3 = half of the time; 4 = most of the time; 5 = all of the time). In part 3, patients were asked to rate their overall vision and their vision at near, intermediate, and distance on a scale ranging from 0 to 10 (0 = worst; 10 = best).
  • abberation and kappa angle [After operation (Month 3)]: iTrace visual function analyzer
  • MTF cut-of and OSI [After operation (Month 3)]: MTF cut-of and OSI values measured by optical quality analysis system \[OQAS\]

+Eligibility

Sex: All, ages: 20 Years to 85 Years

Inclusion Criteria:

* visually significant cataract
* age of 20 years or older
* preoperative corneal astigmatism of 1.50 diopters (D) or lower.

Exclusion Criteria:

* previous ocular surgery
* active ocular pathology
* amblyopia
* systemic or ocular medication that could affect vision
* subclinical or clinical corneal ectatic disease
* pupil abnormalities
* intraoperative complication leading to capsular or zonular abnormalities

+Locations (1)

FacilityCityCountryStatus
Ophthalmology and Optometry HospitalWenzhou, ZhejiangChina

+Publications

  • Results publication: Millan MS, Vega F. Extended depth of focus intraocular lens: Chromatic performance. Biomed Opt Express. 2017 Aug 31;8(9):4294-4309. doi: 10.1364/BOE.8.004294. eCollection 2017 Sep 1. PMID 28966865
  • Results publication: Kaymak H, Hohn F, Breyer DR, Hagen P, Klabe K, Gerl RH, Mueller M, Auffarth GU, Gerl M, Kretz FT. [Functional Results 3 Months after Implantation of an "Extended Range of Vision" Intraocular Lens]. Klin Monbl Augenheilkd. 2016 Aug;233(8):923-7. doi: 10.1055/s-0042-104064. Epub 2016 Jul 6. German. PMID 27385257
  • Results publication: Esteve-Taboada JJ, Dominguez-Vicent A, Del Aguila-Carrasco AJ, Ferrer-Blasco T, Montes-Mico R. Effect of Large Apertures on the Optical Quality of Three Multifocal Lenses. J Refract Surg. 2015 Oct;31(10):666-76. doi: 10.3928/1081597X-20150928-01. PMID 26469074
  • Results publication: Attia MSA, Auffarth GU, Kretz FTA, Tandogan T, Rabsilber TM, Holzer MP, Khoramnia R. Clinical Evaluation of an Extended Depth of Focus Intraocular Lens With the Salzburg Reading Desk. J Refract Surg. 2017 Oct 1;33(10):664-669. doi: 10.3928/1081597X-20170621-08. PMID 28991333
  • Results publication: Attia MS, Khoramnia R, Auffarth GU, Kirchner M, Holzer MP. Near and intermediate visual and reading performance of patients with a multifocal apodized diffractive intraocular lens using an electronic reading desk. J Cataract Refract Surg. 2016 Apr;42(4):582-90. doi: 10.1016/j.jcrs.2015.11.047. PMID 27113882
  • Results publication: Attia MS, Auffarth GU, Khoramnia R, Linz K, Kretz FT. Near and intermediate reading performance of a diffractive trifocal intraocular lens using a reading desk. J Cataract Refract Surg. 2015 Dec;41(12):2707-14. doi: 10.1016/j.jcrs.2015.06.038. PMID 26796451

+Investigators

  • yune zhao, MD, Study chair, Wenzhou Medical University