Continuous Non-Invasive Blood Pressure System Data Collection in Comparison to Invasive Radial Arterial Pressure

NCT04456179 — Not applicable, Completed, 6 participants, Sensifree Ltd.

ClinicalTrials Daily  ·  Areas  ·  Conditions  ·  Drugs  ·  Sponsors  ·  

Evaluation of Sensifree's PPG Based Continuous & Non-Invasive Blood Pressure Monitoring System in Comparison to Invasive Radial Arterial Line

RegistryNCT04456179
StatusCompleted
PhaseNot applicable
Study typeInterventional; non randomized, single group, masking: none, other
Enrollment6 (Actual)
SponsorSensifree Ltd. (Industry)
ConditionsBlood Pressure Measurement
InterventionsGE Datex-Ohmeda Oxy-F Finger Clip Pulse Oximeter Sensor, Arrow® arterial catheterization kit (Teleflex) (Device)
Datesstart 2020-02-03, primary completion 2020-02-06, completion 2020-02-06, first posted 2020-07-02, last updated 2020-07-02
Locations1 site in United States

Related Papers Related Patents Related Grants Related Experts
All trials for Blood Pressure Measurement All trials of GE Datex-Ohmeda Oxy-F Finger Clip Pulse Oximeter Sensor All trials of Arrow® arterial catheterization kit (Teleflex)

-Summary

The purpose of this study is to evaluate methods to modify blood pressure in humans and measure the effectiveness of such methods. A secondary outcome is to evaluate the performance of an investigational continuous non-invasive blood pressure (cNIBP) device created by Sensifree. The tests will per performed in non-hospitalized subjects under varied controlled conditions that include resting blood pressure and non-pharmacologically induced blood pressure changes.

Expand all sections  ·  Collapse all

+Detailed description

On a first visit a screening procedure to verify inclusion / exclusion criteria are met will be conducted. On the primary procedure visit, data collection will begin with the subjects having the investigational device, ECG sensors, and 1 or more pulse oximetry sensors placed on them for data collection and to monitor their safety for the duration of the study. A physician will place an arterial line in the radial artery. The Sensifree cNIBP system will be calibrated with an oscillometric and/or auscultatory blood pressure cuff measurement taken on the arm opposite the arterial line.

A series of blood pressure changes will be induced, including various combinations of methods.

+Arms and interventions

  • GE Datex-Ohmeda Oxy-F Finger Clip Pulse Oximeter Sensor (Device): PPG based, fingertip mounted sensor, that measures the oxygen level (oxygen saturation) of the blood and generates a waveform
  • Arrow® arterial catheterization kit (Teleflex) (Device): Invasive monitoring of blood pressure via catheterization of the radial artery, displaying a continuous pressure waveform

+Outcome measures

Primary outcomes

  • Evaluation of the magnitude of blood pressure change (measured in mmHg) cause by different isometric efforts in humans [3-4 hours per subject]: Measure the effect of a combination of the following isometric efforts on a subject's blood pressure (measured in mmHg): 1. Hand grip 2. Weight lifting 3. Leg static effort

Secondary outcomes

  • Measure the accuracy of an investigational continuous non-invasive blood pressure (cNIBP) device [3-4 hours per subject]: Comparison of BP values (Systolic, Diastolic, MAP) that are calculated by the investigational device to the BP values measured by the arterial line during isometric effort comprising a combination of the following isometric efforts on a subject's blood pressure: 1. Hand grip 2. Weight lifting 3. Leg static effort

+Eligibility

Sex: All, ages: 18 Years to any, accepts healthy volunteers

Inclusion Criteria:

* Subject must have the ability to understand and provide written informed consent
* Subject must be willing and able to comply with study procedures and duration

Exclusion Criteria:

* Subject with a BMI over 39
* Deformities or abnormalities that may prevent proper application of the device under test
* Lateral difference in blood pressure greater than 5mmHg diastolic and 9mmHg systolic
* Tachycardia or resting heart rate less than 45 bpm
* Females who are pregnant, who are trying to get pregnant, (confirmed by positive urine pregnancy test unless the subject is known to be not of child-bearing potential)
* Subjects with known respiratory conditions such as: (self-reported)

  * uncontrolled / severe asthma,
  * flu,
  * pneumonia / bronchitis,
  * shortness of breath / respiratory distress,
  * respiratory or lung surgery,
  * emphysema, COPD, lung disease
* Subjects with known heart or cardiovascular conditions such as: (self-reported, except for blood pressure and ECG review)

  * have had cardiovascular surgery
  * have cardiac pacemakers and/or automatic internal cardio-defibrillator
  * Chest pain (angina)
  * Abnormal pulse pressure
  * previous heart attack
  * blocked artery
  * unexplained shortness of breath
  * congestive heart failure (CHF)
  * history of stroke
  * transient ischemic attack
  * carotid artery disease
  * myocardial ischemia
  * myocardial infarction
  * cardiomyopathy
  * Pulsus Paradoxus
* Self-reported health conditions as identified in the Health Assessment Form (self-reported)

  * diabetes,
  * uncontrolled thyroid disease,
  * kidney disease / chronic renal impairment,
  * history of seizures (except childhood febrile seizures),
  * epilepsy,
  * history of unexplained syncope,
  * recent history of frequent migraine headaches,
  * recent head injury
  * cancer / chemotherapy
* Subjects with known clotting disorders (self-reported)

  * history of bleeding disorders or personal history of prolonged bleeding from injury
  * history of blood clots
  * hemophilia
  * current use of blood thinner: prescription or daily use of aspirin
* Subjects with severe contact allergies to standard adhesives, latex or other materials found in pulse oximetry sensors, ECG electrodes, respiration monitor electrodes or other medical sensors (self-reported)
* Subjects with a contact allergy to ultrasound gel.
* Subjects with prior or known allergies to iodine or lidocaine (or similar pharmacological agents, e.g. Novocaine)
* Failure of the Perfusion Index Ulnar/Ulnar+Radial Ratio test
* Subject is intoxicated during the time of the visit, or was intoxicated within 24 hours prior to study visit, as reported by the subject, or per study staff judgment.
* Other known health condition, should be considered upon disclosure in health assessment form

+Locations (1)

FacilityCityCountryStatus
Clinimark LabLouisville, ColoradoUnited States

+Investigators