DOLPHIN-VIVO: Diagnosis Of LymPHoma IN Vivo (Ex Vivo Phase)

NCT04162431 — Completed, 50 participants, University of Exeter

ClinicalTrials Daily  ·  Areas  ·  Conditions  ·  Drugs  ·  Sponsors  ·  

Diagnosis Of Lymphoma In Vivo Using Vibrational Spectroscopy (Ex Vivo Phase)

RegistryNCT04162431, acronym DOLPHIN-VIVO
StatusCompleted
Study typeObservational
Enrollment50 (Actual)
SponsorUniversity of Exeter (Other); collaborators: Gloucestershire Hospitals NHS Foundation Trust, University of Bristol
ConditionsLymphoma, Head and Neck Cancer
Interventionsspectroscopic measurement, FNA biopsy, histopathology and cytology (Diagnostic test)
Datesstart 2021-06-28, primary completion 2024-06-07, completion 2024-06-07, first posted 2019-11-14, last updated 2024-06-11
Locations1 site in United Kingdom

Related Papers Related Patents Related Grants Related Experts
All trials for Lymphoma All trials for Head and Neck Cancer All trials of spectroscopic measurement All trials of FNA biopsy

-Summary

Lymphoma diagnosis often involves removal and biopsy of one or more lymph nodes. Many (around half) of these diagnostic procedures show that no cancer is present, hence unnecessary removal results in numerous side effects and complications. The procedure is also highly invasive.

The investigators have already shown that it is possible to tell the difference between healthy and diseased tissue in the laboratory by looking at the light emitted by tissue when a low power laser is shone on to it. The investigators intend to use this technique, known as "Raman Spectroscopy" (RS) to tell if tissue in the node is cancerous or healthy. By combining RS with a fine needle, the technique can target tissues below the skin with minimal invasion. Our needle will provide the clinician with instant diagnosis without the delay and cost of a laboratory analysis by pathologists.

The investigators have designed a probe that slides through a fine needle, guided by ultrasound, to the lymph node. The space between the two needles provides space for cell aspirate.

The investigators propose to measure spectra from excess lymph node biopsy samples taken during standard routine diagnostic biopsy.

The investigators are also interested to see if they can successfully extract a fine needle aspiration (FNA) biopsy sample using the device, as well as record a RS measurement. If successful this would ease clinical adoption as the study could run in parallel with existing standard routine clinical practice, using just one device.

This study will evaluate the new device on half a lymph node that will be excised and snap-frozen during a routine surgical biopsy, to gather data for submission of approvals for an in-vivo study to follow.

Expand all sections  ·  Collapse all

+Detailed description

Surplus lymph node tissue collected from patients undergoing routine surgical treatment for head \& neck disease will be investigated using vibrational spectroscopy.

The project will develop a combined FNA/Raman spectroscopy needle probe. This study will evaluate this device on excised lymph node tissue to gather data for submission of approvals for an in-vivo study to follow. Raman \& FTIR (fourier transform infrared) spectra will be correlated with routine histopathology results using multivariate analysis methods. Cytology samples taken using the device will be compared with histopathology results.

Aims

To demonstrate that the FNA/Raman spectroscopy probe device, developed as part of this project, can:

Safely perform measurement of Raman spectra on excised lymph node tissue Safely perform FNA (fine needle aspiration) biopsies on excised lymph node tissue To evaluate the performance of a Raman needle probe to detect lymphoma \& malignancy in excised head \& neck lymph nodes and differentiate from benign nodes.

To develop the investigators understanding of vibrational spectroscopy signal characteristics in head \& neck lymph nodes (through Raman \& FTIR mapping measurements of tissue sections).

Objectives To test a new combined FNA and spectroscopic device on ex vivo tissue in preparation for an in vivo study.

Outcome

Primary Outcome Measures The FNA/Raman spectroscopy probe device can be used safely on excised lymph nodes to measure tissue spectra and collect FNA biopsies.

Diagnostic performance of vibrational spectroscopy for differentiation of lymphoma \& malignant nodes from benign nodes.

Secondary Outcome Measures Evaluation of the performance of a Raman needle probe to detect lymphoma \& malignancy in excised head \& neck lymph nodes and differentiate from benign nodes. To develop the investigators understanding of vibrational spectroscopy signal characteristics in head \& neck lymph nodes (through Raman \& FTIR mapping measurements of tissue sections).

Evaluation of the performance of a Raman needle probe to measure head \& neck lymph nodes (ergonomic design, ease of use etc.).

+Arms and interventions

ArmTypeInterventionsDescription
non-hodgkin lymphomaDiagnostic Test: spectroscopic measurement; Diagnostic Test: FNA biopsy; Diagnostic Test: histopathology and cytologypatients diagnosed with non-hodgkin lymphoma
hodgkin lymphomaDiagnostic Test: spectroscopic measurement; Diagnostic Test: FNA biopsy; Diagnostic Test: histopathology and cytologypatients diagnosed with hodgkin lymphoma
squamous cell carcinomaDiagnostic Test: spectroscopic measurement; Diagnostic Test: FNA biopsy; Diagnostic Test: histopathology and cytologypatients diagnosed with squamous cell carcinoma
reactiveDiagnostic Test: spectroscopic measurement; Diagnostic Test: FNA biopsy; Diagnostic Test: histopathology and cytologypatients diagnosed with a reactive (non-cancerous) lymph node
otherDiagnostic Test: spectroscopic measurement; Diagnostic Test: FNA biopsy; Diagnostic Test: histopathology and cytologynone of the above. Other cancer and non-cancer conditions
  • spectroscopic measurement (Diagnostic test), also known as raman, infra red: measurement of the tissue with spectroscopy
  • FNA biopsy (Diagnostic test), also known as fine needle aspiration biopsy: a fine needle aspiration (FNA) biopsy will be taken
  • histopathology and cytology (Diagnostic test): Histopathology and cytology will be performed on the samples

+Outcome measures

Primary outcomes

  • Safe spectroscopic measurement [3 years]: The FNA/Raman spectroscopy probe device can be used safely on excised lymph nodes to measure tissue spectra and collect FNA biopsies.
  • Diagnostic discrimination [3 years]: Diagnostic performance of vibrational spectroscopy for differentiation of lymphoma \& malignant nodes from benign nodes

Secondary outcomes

  • Cancer Performance evaluation [3 years]: Evaluation of the performance of a Raman needle probe to detect lymphoma \& malignancy in excised head \& neck lymph nodes and differentiate from benign nodes
  • Understanding of Raman on lymph nodes [3 years]: To develop our understanding of vibrational spectroscopy signal characteristics in head \& neck lymph nodes (through Raman \& FTIR mapping measurements of tissue sections).
  • General Performance evaluation [3 years]: Evaluation of the performance of a Raman needle probe to measure head \& neck lymph nodes (ergonomic design, ease of use etc.)

+Eligibility

Sex: All, ages: 18 Years to any, accepts healthy volunteers

Inclusion Criteria:

* Patients undergoing biopsy or excision of lymph nodes as part of their routine clinical care within Gloucestershire Hospitals NHS Foundation Trust.
* Patients undergoing lymphadenectomy as part of routine treatment

Exclusion Criteria:

* Patients unable to consent to the study due to communication difficulties
* Patients unable to consent to the study due to lack of capacity

+Locations (1)

FacilityCityCountryStatus
Gloucestershire Hospitals NHS Foundation TrustGloucester, GloucestershireUnited Kingdom

+Investigators