Project My Heart Your Heart: Pacemaker Reuse

NCT04016870 — Not applicable, Active not recruiting, 370 participants, University of Michigan

ClinicalTrials Daily  ·  Areas  ·  Conditions  ·  Drugs  ·  Sponsors  ·  

Project My Heart Your Heart: Prospective Evaluation of the Safety and Efficacy of Cardiac Pacemaker Reuse in Low to Middle Income Countries

RegistryNCT04016870, acronym MHYH
StatusActive not recruiting
PhaseNot applicable
Study typeInterventional; randomized, parallel, masking: single, treatment
Enrollment370 (Estimated)
SponsorUniversity of Michigan (Other)
ConditionsDevice Related Infection, Device Malfunction, Bradycardia
InterventionsReconditioned Pacemaker, New Pacemaker (Device)
Datesstart 2018-10-13, primary completion 2026-01-01 (estimated), completion 2026-01-01 (estimated), first posted 2019-07-12, last updated 2025-07-04
Locations8 sites in Kenya, Mexico, Mozambique, Nigeria, Paraguay, Sierra Leone, Venezuela

Related Papers Related Patents Related Grants Related Experts
All trials for Device Related Infection All trials for Device Malfunction All trials of Reconditioned Pacemaker All trials of New Pacemaker

-Summary

Lack of access to pacemakers is a major challenge to the provision of cardiovascular health care in Low and Middle Income Countries (LMIC). Post-mortem pacemaker utilization could be safe, efficacious, and ethically responsible means of delivering the needed care. Reconditioned pacemakers can provide therapy for patients with symptomatic bradycardia and no means of receiving a new device. The objective of the clinical trial is to determine if pacemaker reutilization can be shown to be a safe means of delivering pacemakers to patients in LMIC without resources. Consented patients in this multi-center trial will be randomized to undergo implantation of either a reconditioned device or a new device.

Expand all sections  ·  Collapse all

+Arms and interventions

ArmTypeInterventionsDescription
New DeviceActive comparatorDevice: New PacemakerNew pacemakers will be sourced from pacemaker manufacturers.
Reconditioned DeviceExperimentalDevice: Reconditioned PacemakerDonated devices are inspected according to specific protocols that evaluate physical and electrical (battery longevity) suitability for future use. Devices deemed to be acceptable are shipped to a third-party vendor (NEScientific) for disassembly, cleaning and re-sterilization.
  • Reconditioned Pacemaker (Device), also known as St. Jude Medical device, Boston Scientific device, Medtronic device: Devices from the three manufacturers below will be used.
  • New Pacemaker (Device), also known as St. Jude Medical device, Boston Scientific device, Medtronic device, Biotronik device: Devices from the four manufacturers below will be used.

+Outcome measures

Primary outcomes

  • Freedom from Procedure-Related Infection at 12 months [12 months post device implantation]: Clinical evidence of pacemaker infection includes local signs of inflammation at the generator site such as erythema, warmth, fluctuance, tenderness, purulent drainage, wound dehiscence, or erosion. Device related endocarditis will be reported if the Duke criteria for infective endocarditis are met. Procedure-related infections will be classified as follows: pocket infection, endocarditis, recurrent bacteremia, extrusion of wires or generator

Secondary outcomes

  • Freedom from Pacemaker Software or Hardware Malfunction at 12 months [12 months post device implantation]: Pacemaker software or hardware malfunction include unexpected premature battery depletion, device or electrode malfunction, or unexplained patient death.

+Eligibility

Sex: All, ages: 18 Years to any

Inclusion Criteria:

* Life expectancy ≥ 2 years.
* Indications for device implantation must be fulfilled per standard of care. Consistent with 2008 American College of Cardiology / American Heart Association guidelines for device therapy, one of the following class I indications must be met.
* Sinus Node Dysfunction
* Acquired Atrioventricular (AV) Block
* Chronic Bifascicular Block
* Hypersensitive Carotid Syndrome
* Lack of financial ability to pay for a new device must be assessed and documented.
* All other methods of new device acquisition must be exhausted.
* Patient must be agreeable and able to follow-up with the implanting center within 2 weeks for wound check, at 2 months, 6 months, and every 6 months thereafter for routine pacemaker checks.

Exclusion Criteria:

* Severe valvular disease
* Severe pulmonary disease
* End-stage renal disease (creatinine clearance < 30 mL/min) whether or not on dialysis
* Evidence of ongoing systemic infection
* Prior pacemaker or implantable cardioverter-defibrillator implantation
* Significant contraindication to pacemaker implantation per evaluation of the implanting physician (very high risk of complications).
* Presence of any other condition that the local investigator feels would be problematic or would restrict or limit the participation of the patient for the entire study period
* Pregnant women

+Locations (8)

FacilityCityCountryStatus
The Moi Teaching and Referral HospitalEldoretKenya
Universidad Autonoma de Nuevo LeonMonterreyMexico
Hospital Central de MaputoMaputoMozambique
LASUTHIkeja, LagosNigeria
Port Harcourt Teaching HospitalPort Harcourt, Rivers StateNigeria
FUNDACORAsunciónParaguay
Choithram Memorial HospitalFreetownSierra Leone
ASCARDIOBarquisimeto, LaraVenezuela