TrialReader


Comparison of Two Different Videolaryngoscopes Regarding Hemodynamic Parameters in Open Heart Surgey

NCT03483285 — Not applicable, Completed, 50 participants, Kocaeli University

ClinicalTrials Daily  ·  Areas  ·  Conditions  ·  Drugs  ·  Sponsors  ·  

Videolaryngoscopes in Open Heart Surgery

RegistryNCT03483285
StatusCompleted
PhaseNot applicable
Study typeInterventional; randomized, parallel, masking: double, diagnostic
Enrollment50 (Actual)
SponsorKocaeli University (Other)
ConditionsIntubation;Difficult, Coronary Bypass
Interventionsairtraq, storz (Device)
Datesstart 2018-04-01, primary completion 2019-03-20, completion 2019-03-21, first posted 2018-03-30, last updated 2021-02-17
Locations1 site in Turkey (Türkiye)

Related Papers Related Patents Related Grants Related Experts
AI Assistant Save
All trials for Intubation;Difficult All trials for Coronary Bypass All trials of airtraq All trials of storz

-Summary

Endotracheal intubation increased the heart rate and blood pressure in normal patients. Open heart surgery patients are more prone to hemodynamic variability. In addition, they have increased possibility for difficult intubation The heart rate and blood pressure increase impaired the oxygen consumption. This was previously shown that Videolaryngoscopes minimaly effects the vital signs in normal patients. Videolaryngoscopy inreased the rate of success in normal and difficult airway. This study aimed to compare two laryngoscopes regarding hemodynamic parameters and intubation times in coronary bypass surgery.

Expand all sections  ·  Collapse all

+Detailed description

Aim: Endotracheal intubation increased the heart rate and blood pressure in normal patients. Open heart surgery patients are more prone to hemodynamic variability. In addition, they have increased possibility for difficult intubation The heart rate and blood pressure increase impaired the oxygen consumption. This was previously shown that Videolaryngoscopes minimaly effects the vital signs in normal patients. Videolaryngoscopy inreased the rate of success in normal and difficult airway. This study aimed to compare two laryngoscopes regarding hemodynamic parameters and intubation times in coronary bypass surgery.

Material and methods: 50 patients undergoing coronary bypass surgery enrolled in this prospective.randomized study. Demogaphic variables and airway characteristics of patients were recorded. Glottic visulisation and intubation time were recorded. Systolic blood pressure, diastolic blood pressure, mean arterial pressure and heart rate were recorded 2 minutes intervals before intubation, after intubation during 10 minutes.

+Arms and interventions

ArmTypeInterventionsDescription
heart rateActive comparatorDevice: airtraq; Device: storzEffects of İntubation with Airtraq or Storz to heart rate
mean arterial pressureActive comparatorDevice: airtraq; Device: storzEffect of intubation with Airtraq or Storz to mean arterial pressure
  • airtraq (Device): airtraq videolaryngoscope
  • storz (Device): storz videolaryngoscope

+Outcome measures

Primary outcomes

  • heart rate [2 months]: heart rate

Secondary outcomes

  • insertion time [2 months]: optimal glottic visualisation time
  • intubation time [2 months]: intubation time
  • mean arterial pressure [2 months]: mean arterial pressure

+Eligibility

Sex: All, ages: 18 Years to 90 Years

Inclusion Criteria:

* patients undergoing open heart surgery
* < 18 years of age

Exclusion Criteria:

* emergency

+Locations (1)

FacilityCityCountryStatus
Kocaeli University HospitalKocaeliTurkey (Türkiye)

+Investigators

My Notes