TrialReader


Comparison of PET/CT vs. PET/MRI Using 2 Radiopharmaceuticals

NCT03125629 — Phase 2, Completed, 53 participants, Stanford University

ClinicalTrials Daily  ·  Areas  ·  Conditions  ·  Drugs  ·  Sponsors  ·  

Comparison of PET/CT vs. PET/MRI

RegistryNCT03125629
StatusCompleted
PhasePhase 2
Study typeInterventional; non randomized, parallel, masking: none, diagnostic
Enrollment53 (Actual)
SponsorStanford University (Other)
ConditionsCancer Diagnosis, Diagnostic Techniques and Procedures, Diagnostic Imaging
InterventionsF-18 FDG, Ga-68-DOTA-TATE, Positron Emission Tomography / Computed Tomography (PET/CT) Scan, Positron Emission Tomography / Magnetic Resonance Imaging (PET/MRI) Scan (Drug, device)
Datesstart 2014-05-27, primary completion 2016-11-30, completion 2020-02-05, first posted 2017-04-24, last updated 2021-04-09
Locations1 site in United States

Related Papers Related Patents Related Grants Related Experts
AI Assistant Save
All trials for Cancer Diagnosis All trials for Diagnostic Techniques and Procedures All trials of F-18 FDG All trials of Ga-68-DOTA-TATE

-Summary

This clinical trial studies how well positron emission tomography (PET)/computed tomography (CT) works compared to PET/magnetic resonance imaging (MRI) in evaluating patients with cancer. PET/CT and PET/MRI may determine which scanner is best for the patient's type of cancer and other types of cancers.

Expand all sections  ·  Collapse all

+Detailed description

PRIMARY OBJECTIVES:

I. To evaluate if PET/CT and PET/MRI scanners provide equivalent results for evaluation of cancer patients.

OUTLINE:

Patients receive standard of care 18F-fludeoxyglucose (FDG) or Ga68-DOTA-TATE intravenously (IV). Within 45-60 minutes, patients then undergo PET/CT imaging immediately followed by PET/MRI. Each participant is to receive 18-FDG or 68Ga-DOTA-TATE only, no participant was to receive both radiotracers.

+Arms and interventions

ArmTypeInterventionsDescription
18F-FDG PET/CT ScanExperimentalDrug: F-18 FDG; Device: Positron Emission Tomography / Computed Tomography (PET/CT) ScanParticipants will undergo a PET/CT scan with radiolabel 18F-FDG.
18F-FDG PET/MRI ScanExperimentalDrug: F-18 FDG; Device: Positron Emission Tomography / Magnetic Resonance Imaging (PET/MRI) ScanParticipants will undergo a PET/MRI scan with radiolabel 18F-FDG.
68Ga-DOTA-TATE PET/CT ScanExperimentalDrug: Ga-68-DOTA-TATE; Device: Positron Emission Tomography / Computed Tomography (PET/CT) ScanParticipants will undergo a PET/CT scan with radiolabel 68Ga-DOTA-TATE.
68Ga-DOTA-TATE PET/MRI ScanExperimentalDrug: Ga-68-DOTA-TATE; Device: Positron Emission Tomography / Magnetic Resonance Imaging (PET/MRI) ScanParticipants will undergo a PET/MRI scan with radiolabel 68Ga-DOTA-TATE.
  • F-18 FDG (Drug): Radiolabel for positron emission tomography / computed tomography (PET/CT) and computed tomography (PET/CT) imaging
  • Ga-68-DOTA-TATE (Drug): Radiolabel for positron emission tomography / computed tomography (PET/CT) and computed tomography (PET/CT) imaging
  • Positron Emission Tomography / Computed Tomography (PET/CT) Scan (Device): Scan using a regular medical care (IDE-exempt) Discovery 600 / 690 PET/CT scanner.
  • Positron Emission Tomography / Magnetic Resonance Imaging (PET/MRI) Scan (Device): Scan using a NOVEL GE PET/MRI scanner.

+Outcome measures

Primary outcomes

  • Absolute Accuracy of SUV Max of PET/CT vs PET/MRI [4 hours]: Standardized uptake value max (SUVmax) is a measurement of the maximum radiopharmaceutical uptake value within the region of interest (ROI). SUVmax is calculated as the ratio of activity concentration:injected dose/body weight. The outcome is reported as the mean SUVmax with standard deviation (SD), reported for 8 specific organs or bodily locations.

Secondary outcomes

  • PET/CT vs PET/MRI Difference in Standardized Uptake Value Max (SUVmax), by Radiotracer [estimated average of 2 hours]: Standardized uptake value max (SUVmax) is a measurement of the maximum radiopharmaceutical uptake within the region of interest (ROI). Relative accuracy of a particular radiotracer in a particular tissue is determined by expressing the absolute accuracy (obtained in the primary outcome measure) in terms of percent difference between SUVmax values obtained from PET/CT and PET/MR. Percentage difference is expressed as the difference of the means in SUVmax for the PET/CT and PET/MRI scan procedures for the particular radiotracer, divided by the mean between the values for the 2 scan procedures. The closer the percent difference is to 0%, the better the agreement between the two scanners. The outcome is expressed as the percentage difference, a number without dispersion.

+Eligibility

Sex: All, ages: 18 Years to any

INCLUSION CRITERIA

* Cancer diagnosis
* Capable of complying with study procedures
* Able to remain still for duration of imaging procedure (approximately 90 minutes total)
* Written informed consent

EXCLUSION CRITERIA

* Pregnant or nursing
* Metallic implants
* Impaired renal function

+Posted results

Participant flow

MilestoneTotal Participant Flow
Started53
Completed50
Not completed3

Outcome results

  • Absolute Accuracy of SUV Max of PET/CT vs PET/MRI (Primary), Mean, ratio: 18F-FDG PET/CT Scan 1.78 +/- 0.42; 18F-FDG PET/MRI Scan 1.08 +/- 0.38; 68Ga-DOTA-TATE PET/CT Scan 0.54 +/- 0.22; 68Ga-DOTA-TATE PET/MRI Scan 0.51 +/- 0.19
  • PET/CT vs PET/MRI Difference in Standardized Uptake Value Max (SUVmax), by Radiotracer (Secondary), Number, Percentage difference: 18-FDG PET/CT and PET/MRI 48.95; 68Ga DOTA-TATE PET/CT and PET/MRI 5.71

Adverse events

Time frame: 1 day

ArmDeathsSerious adverse eventsOther adverse events
18F-FDG PET/CT Scan0/44 (0.0%)0/44 (0.0%)0/44 (0.0%)
18F-FDG PET/MRI Scan0/42 (0.0%)0/42 (0.0%)0/42 (0.0%)
68Ga-DOTA-TATE PET/CT Scan0/6 (0.0%)0/6 (0.0%)0/6 (0.0%)
68Ga-DOTA-TATE PET/MRI Scan0/6 (0.0%)0/6 (0.0%)0/6 (0.0%)

+Locations (1)

FacilityCityCountryStatus
Stanford University, School of MedicinePalo Alto, CaliforniaUnited States

+Study documents

+Investigators

My Notes