TrialReader


Yttrium-90 (Y90) Glass Microspheres PET/CT in Imaging Patients With Liver Tumors

NCT03109262 — Not applicable, Completed, 42 participants, Stanford University

ClinicalTrials Daily  ·  Areas  ·  Conditions  ·  Drugs  ·  Sponsors  ·  

High Quality Imaging and Dosimetry of Yttrium-90 (90Y) SIRT Using a Digital PET/CT

RegistryNCT03109262
StatusCompleted
PhaseNot applicable
Study typeInterventional; na, single group, masking: none, diagnostic
Enrollment42 (Actual)
SponsorStanford University (Other)
ConditionsPrimary Malignant Liver Neoplasm
InterventionsComputed Tomography (CT), Positron Emission Tomography (PET), 90-Yttrium (Y-90) Glass Microspheres, Technetium 99mTc albumin aggregated (99mTc-MAA), Single-photon emission computerized tomography (SPECT) scan (Procedure, device, diagnostic test)
Datesstart 2017-02-15, primary completion 2019-05-30, completion 2021-02-28, first posted 2017-04-12, last updated 2022-01-10
Locations1 site in United States

Related Papers Related Patents Related Grants Related Experts
AI Assistant Save
All trials for Primary Malignant Liver Neoplasm All trials of Computed Tomography (CT) All trials of Positron Emission Tomography (PET)

-Summary

This clinical trial studies how well yttrium-90 (Y90) glass microspheres positron emission tomography (PET)/computed tomography (CT) works in imaging patients with liver tumors . Images produced by PET/CT may provide better information about the distribution of particles, such as Y90 glass microspheres, delivered for selective internal radiation therapy (SIRT) as compared to regular medical care images useing technetium Tc-99m albumin-aggregated single photon emission computed tomography (SPECT)/CT images.

Expand all sections  ·  Collapse all

+Detailed description

PRIMARY OBJECTIVES:

I. To evaluate the image quality of yttrium-90 (Y90) microspheres PET/CT post SIRT images as compared to technetium Tc-99m albumin aggregated (99mTc MAA) SPECT/CT.

SECONDARY OBJECTIVES:

I. To determine the superior accuracy in both distribution and dosimetry of Y90 PET/CT post-SIRT imaging compared to 99mTc MAA planar and SPECT/CT imaging.

OUTLINE:

Immediately after standard of care SIRT, patients receive Y90 glass microspheres and undergo PET/CT over 30 minutes.

This study compares the experimental images to the regular medical care images in the same participant.

+Arms and interventions

ArmTypeInterventionsDescription
Yttrium Y-90 PET/CT vs 99mTc-MAA SPECT/CT ScansExperimentalProcedure: Computed Tomography (CT); Procedure: Positron Emission Tomography (PET); Device: 90-Yttrium (Y-90) Glass Microspheres; Diagnostic Test: Technetium 99mTc albumin aggregated (99mTc-MAA); Procedure: Single-photon emission computerized tomography (SPECT) scanAll participants receive both Y-90 PET/CT vs 99mTc-MAA SPECT/CT Scans
  • Computed Tomography (CT) (Procedure), also known as CAT, CAT Scan, Computed Tomography, Computerized Axial Tomography, Computerized Tomography, CT, CT SCAN, tomography, X-ray: As part of PET/CT and SPECT/CT scans.
  • Positron Emission Tomography (PET) (Procedure), also known as Medical Imaging, Positron Emission Tomography, PET, PET SCAN, Positron Emission Tomography, Positron Emission Tomography Scan, Positron-Emission Tomography, proton magnetic resonance spectroscopic imaging: As part of PET/CT scan
  • 90-Yttrium (Y-90) Glass Microspheres (Device), also known as TheraSphere: Radiolabel for PET/CT scan
  • Technetium 99mTc albumin aggregated (99mTc-MAA) (Diagnostic test), also known as 99mTc-MAA: Radiolabel for 99mTc-MAA SPECT/CT Scan
  • Single-photon emission computerized tomography (SPECT) scan (Procedure), also known as SPECT Scan: As part of SPECT/CT scan

+Outcome measures

Primary outcomes

  • Image Quality for 90-Y PET/CT Scans [1 day]: Image quality for 90Y PET/CT scan images was assessed relative to the expected image quality of Standard of Care (SoC) 99mTc-MAA SPECT/CT scans obtained from the same participant. Assessments were conducted at 5, 10, 15 and 20 minutes after infusion. Scans were assessed on a 1 to 5 Likert scale by 2 Nuclear Medicine physicians who were blinded to patient information. The Likert scale for image quality was established as follows: 1. = Non-diagnostic 2. = Suboptimal 3. = Acceptable 4. = Good 5. = Excellent, equivalent to a SoC 99mTc-MAA SPECT/CT scan The scans for each individual participant at each timepoint was scored on the Likert scale, as determined by the 2 Nuclear Medicine physicians. The outcome is reported as the overall mean of the physician determinations for each time point, with standard deviation.

Secondary outcomes

  • Radiopharmaceutical Dosimetry Accuracy for 90-Y PET/CT Scans and 99mTc-MAA SPECT/CT Scans [1 day]: Radiopharmaceutical dosimetry was assessed based on the numerical tumor-absorbed dose value in Gray as calculated by SurePlan (MIM Software Inc, Cleveland, Ohio). The outcome is reported as the median tumor-absorbed dose in Gray for each scan method (90Y PET/CT and 99mTc-MAA SPECT/CT), with standard deviation.

+Eligibility

Sex: All, ages: 18 Years to any

Inclusion Criteria:

* Patient provides written informed consent
* Patient is referred for 90Y SIRT radioembolization of liver tumor(s)
* Patient is capable of complying with study procedures
* Patient is able to remain still for duration of imaging procedure (approximately 30 minutes total for digital PET/CT)

Exclusion Criteria:

* Patient is pregnant or nursing

+Posted results

Participant flow

MilestoneYttrium Y-90 PET/CT vs 99mTc-MAA SPECT/CT Scans
Started42
Completed42
Not completed0

Outcome results

  • Image Quality for 90-Y PET/CT Scans (Primary), Mean, units on a scale: Yttrium Y-90 PET/CT vs 99mTc-MAA SPECT/CT Scans 3.56 +/- 0.43
  • Radiopharmaceutical Dosimetry Accuracy for 90-Y PET/CT Scans and 99mTc-MAA SPECT/CT Scans (Secondary), Median, Gray: Yttrium Y-90 PET/CT 142.9 +/- 99.7; 99mTc-MAA SPECT/CT Scans 118.9 +/- 91.0

Adverse events

Time frame: 1 day

ArmDeathsSerious adverse eventsOther adverse events
Yttrium Y-90 PET/CT vs 99mTc-MAA SPECT/CT Scans0/42 (0.0%)0/42 (0.0%)0/42 (0.0%)

+Locations (1)

FacilityCityCountryStatus
Stanford UniversityPalo Alto, CaliforniaUnited States

+Publications

  • Results publication: Duan H, Khalaf MH, Ferri V, Baratto L, Srinivas SM, Sze DY, Iagaru A. High quality imaging and dosimetry for yttrium-90 (90Y) liver radioembolization using a SiPM-based PET/CT scanner. Eur J Nucl Med Mol Imaging. 2021 Jul;48(8):2426-2436. doi: 10.1007/s00259-021-05188-4. Epub 2021 Jan 14. PMID 33443618

+Study documents

+Investigators

My Notes