Plexa ICD Lead Registry

NCT03103503 — Terminated, 901 participants, Biotronik, Inc.

ClinicalTrials Daily  ·  Areas  ·  Conditions  ·  Drugs  ·  Sponsors  ·  
RegistryNCT03103503
StatusTerminated - Collection of long term lead performance is being transferred to an alternate data collection methodology.
Study typeObservational
Enrollment901 (Actual)
SponsorBiotronik, Inc. (Industry)
ConditionsImplantable Defibrillator User
Datesstart 2017-05-18, primary completion 2019-09-27, completion 2019-09-27, first posted 2017-04-06, last updated 2020-10-14
Locations28 sites in United States

Related Papers Related Patents Related Grants Related Experts
All trials for Implantable Defibrillator User

-Summary

The purpose of this registry is to confirm the long-term safety and reliability of BIOTRONIK's Plexa ICD lead.

Expand all sections  ·  Collapse all

+Outcome measures

Primary outcomes

  • Percentage of Subjects Free From Plexa Lead Related Adverse Events [Up to 2.5 years]: Evaluate the percentage of subjects without an adverse event related to the Plexa lead through study termination. The endpoint is analyzed as the adverse event free-rate. All protocol defined adverse events that occurred more than 30 days after implant and determined to be related to the Plexa lead plus required invasive intervention to resolve or were related to a lead integrity or clinical performance issue were included. Events meeting this criteria but occurring within 30 days were also included except for lead dislodgement, high pacing threshold, failure to capture, or intermittent capture.

Secondary outcomes

  • Plexa Lead Safety-Individual Adverse Events [Up to 2.5 years]: Evaluate the individual types of adverse events contributing to primary outcome measure 'Percentage of Subjects Free From Plexa Lead Related Adverse Events'
  • Pacing Threshold Measurements for the Plexa Lead Through Study Termination [Up to 2.5 years]: Pacing threshold measurements at pulse width of 0.4 for the Plexa leads at completed follow-up visits.
  • Sensing Measurements for the Plexa Lead Through Study Termination [Up to 2.5 years]: Sensing measurements for the Plexa leads at completed follow-up visits.
  • Pacing Impedance Measurements for the Plexa Lead Through Study Termination [Up to 2.5 years]: Pacing impedance measurements for the Plexa leads at completed follow-up visits.
  • Shock Impedance for the Plexa Lead Through Study Termination [Up to 2.5 years]: Shock impedance measurements for the Plexa leads at completed follow-up visits.
  • Percentage of Subjects Free From Protocol Defined Adverse Events [Up to 2.5 years]: Evaluate the percentage of subjects without a protocol defined and clinical event committee adjudicated adverse event, excluding events included in the primary outcome 'Percentage of Subjects Free From Plexa Lead Related Adverse Events', through study termination. Lead dislodgements, high pacing threshold, failure to capture, and intermittent capture related to the Plexa lead that occurred less than or equal to 30 days after lead implant or a lead revision procedure are included here. The endpoint is analyzed as the adverse event free-rate.

+Eligibility

Sex: All, ages: 18 Years to any

Inclusion Criteria:

* Successfully implanted with a BIOTRONIK ICD or CRT-D compatible system along with the Plexa lead no more than 30 days prior to consent
* Able to understand the nature of the registry and provide informed consent
* Available for follow-up visits on a regular basis at the study site for the expected 5 years of follow-up
* Accepts BIOTRONIK Home Monitoring® concept
* Age greater than or equal to 18 years

Exclusion Criteria:

* Enrolled in any investigational cardiac device trial
* Enrolled in BIOTRONIK's QP ExCELs lead study
* Planned cardiac surgical procedures or interventional measures within the next 6 months
* Expected to receive heart transplantation or ventricular assist device within 1 year
* Life expectancy of less than 1 year
* Patients reporting pregnancy at the time of enrollment

+Posted results

Participant flow

MilestoneBIOTRONIK Plexa ICD Lead
Started901
Completed0
Not completed901

Outcome results

  • Percentage of Subjects Free From Plexa Lead Related Adverse Events (Primary), Number, percentage of participants: BIOTRONIK Plexa ICD Lead 100.00 (99.49 to 100.00)
  • Plexa Lead Safety-Individual Adverse Events (Secondary)
  • Pacing Threshold Measurements for the Plexa Lead Through Study Termination (Secondary), Mean, V: BIOTRONIK Plexa ICD Lead 0.63 +/- 0.28
  • Sensing Measurements for the Plexa Lead Through Study Termination (Secondary), Mean, mV: BIOTRONIK Plexa ICD Lead 15.88 +/- 5.56
  • Pacing Impedance Measurements for the Plexa Lead Through Study Termination (Secondary), Mean, ohms: BIOTRONIK Plexa ICD Lead 567.1 +/- 111.2
  • Shock Impedance for the Plexa Lead Through Study Termination (Secondary), Mean, ohms: BIOTRONIK Plexa ICD Lead 75.1 +/- 13.7
  • Percentage of Subjects Free From Protocol Defined Adverse Events (Secondary), Number, percentage of participants: BIOTRONIK Plexa ICD Lead 95.12 (93.49 to 96.36)

Adverse events

Time frame: Though study exit or study termination, an average of 1.1 years

ArmDeathsSerious adverse eventsOther adverse events
BIOTRONIK Plexa ICD Lead64/901 (7.1%)44/901 (4.9%)12/901 (1.3%)

Serious adverse events by term

TermOrgan systemBIOTRONIK Plexa ICD Lead
HematomaSurgical and medical procedures3/901
InfectionInfections and infestations11/901
Loose set-screwSurgical and medical procedures3/901
Non-healing pocket dehiscence requiring interventionSurgical and medical procedures1/901
Cardiogenic shock during implantationSurgical and medical procedures1/901
Operation wound bleedingSurgical and medical procedures1/901
Venous occlusion associated with the implant procedureSurgical and medical procedures1/901
LV lead related high pacing thresholdCardiac disorders1/901
LV lead related lead dislodgementCardiac disorders1/901
Twiddler's syndromeGeneral disorders2/901
RV lead related lead dislodgementCardiac disorders12/901
RV lead related other: high defibrillation threshold.no evidence for lead malfunctionCardiac disorders1/901
RA lead related lead dislodgementCardiac disorders5/901
Pulmonary EmboliGeneral disorders1/901
RV lead related high pacing thresholdCardiac disorders1/901
RV lead related intermittent captureCardiac disorders1/901
RV lead related lead impedance out of range, highCardiac disorders1/901
RV lead related lead undersensingCardiac disorders1/901

Other adverse events by term

TermOrgan systemBIOTRONIK Plexa ICD Lead
HematomaSurgical and medical procedures2/901
Non-healing pocket dehiscence requiring interventionSurgical and medical procedures1/901
Slow wound healing, no sign for infectionSurgical and medical procedures1/901
ThrombosisSurgical and medical procedures1/901
LV lead related extracardiac stimulationCardiac disorders1/901
LV lead related lead impedance out of range, highCardiac disorders1/901
RV lead related lead dislodgementCardiac disorders1/901
RV lead related other: positional atrial undersensingCardiac disorders1/901
Skin erosionSkin and subcutaneous tissue disorders1/901
RA lead related lead dislodgementCardiac disorders1/901
RA lead related no captureCardiac disorders2/901

+Locations (28)

FacilityCityCountryStatus
Thomas Hospital Research OfficeFairhope, AlabamaUnited States
Jeffrey S Goodman MDLos Angeles, CaliforniaUnited States
Eisenhower Desert CardiologyRancho Mirage, CaliforniaUnited States
Florida HospitalOrlando, FloridaUnited States
Advent Health TampaTampa, FloridaUnited States
St. Louis Cardiology ConsultantsAlton, IllinoisUnited States
University of Iowa Hospitals and ClinicsIowa City, IowaUnited States
Heartland CardiologyWichita, KansasUnited States
Research Integrity LLCOwensboro, KentuckyUnited States
Northern Light CardiologyBangor, MaineUnited States
University of MichiganAnn Arbor, MichiganUnited States
Metro Health HospitalWyoming, MichiganUnited States
Michigan HeartYpsilanti, MichiganUnited States
Mercy Clinic CardiologySpringfield, MissouriUnited States
St. Louis Heart and VascularSt Louis, MissouriUnited States
Gateway Cardiovascular Research CenterSt Louis, MissouriUnited States
Mercy Clinic Heart and VascularSt Louis, MissouriUnited States
Glacier View Research Institute CardiologyKalispell, MontanaUnited States
Deborah Heart and Lung CenterBrowns Mills, New JerseyUnited States
Novant HealthWinston-Salem, North CarolinaUnited States
Sanford Medical CenterFargo, North DakotaUnited States
The Ohio State Wexner Medical CenterColumbus, OhioUnited States
Toledo CardiologyToledo, OhioUnited States
The Arrhythmia InstituteNewtown, PennsylvaniaUnited States
Upstate CardiologyGreenville, South CarolinaUnited States
Carolina Heart SpecialistsLancaster, South CarolinaUnited States
Carolina Cardiology AssociatesRock Hill, South CarolinaUnited States
Cardiovascular Associates LtdVirginia Beach, VirginiaUnited States

+Study documents