REspiration Patterns in REVEAL LINQ Insertable Cardiac Monitor
| Registry | NCT02828735, acronym EPIQ |
|---|---|
| Status | Completed |
| Phase | Not applicable |
| Study type | Interventional; na, single group, masking: none, diagnostic |
| Enrollment | 20 (Actual) |
| Sponsor | Medtronic BRC (Industry) |
| Conditions | Breathing Exercises |
| Interventions | respiration assessment (Device) |
| Dates | start 2017-01-30, primary completion 2017-11-20, completion 2017-11-20, first posted 2016-07-12, last updated 2018-06-21 |
| Locations | 1 site in South Africa |
Related Papers Related Patents Related Grants Related Experts
All trials for Breathing Exercises All trials of respiration assessment
The purpose of the study is to evaluate the use of subcutaneous impedance measured with an implanted Medtronic Reveal LINQ™ insertable cardiac monitor (ICM) as respiratory rate monitor.
| Arm | Type | Interventions | Description |
|---|---|---|---|
| Respiration assessment | Other | Device: respiration assessment |
Sex: All, ages: 18 Years to any
Inclusion Criteria: * Suspected arrhythmia Diastolic Heart Failure and/or in Renal Failure. * Chronic Kidney Disease (CKD) in Stage 5 (GFR = <15 mL/min). * Diastolic Heart Failure in class II and class III (class IV to be considered in end stage and non-reversible). * Willing to sign the informed consent form. * Greater than 18 years of age. Exclusion Criteria: * Enrolled in another study that could confound the results of this study, without documented pre-approval from a Medtronic study manager. * Significant respiratory diseases such as COPD or pulmonary hypertension. * Frequent arrhythmias, including PVC's. * Known systolic heart failure. * Recent infection. * Allergenic or rejection reaction to materials used in incision/insertion tools, Reveal LINQ™ ICM exterior or incision closure method. * Active implanted cardiac medical device (e.g. IPG, ICD, CRT, etc). * Not suitable for Reveal LINQ™ implantation (e.g., severe cachexia, dermatologic conditions of the skin) or any concomitant condition which in the opinion of the investigator would not allow a safe participation in the study. * Body conditions that would complicate accurate measurement of respiratory efforts with an external device deployed around the chest. * Not able to take the postures as necessary for the study protocol and not able to walk continuously for a period of 6 minutes. * Any concomitant condition which in the opinion of the investigator would not allow a safe participation in the study.
| Facility | City | Country | Status |
|---|---|---|---|
| Groote Schuur Hospital | Cape Town | South Africa |