Using Ex-vivo Normothermic Machine Perfusion With the Organox Metra™ Device to Store Human Livers for Transplantation

NCT02478151 — Phase 1, Unknown, 40 participants, University Health Network, Toronto

ClinicalTrials Daily  ·  Areas  ·  Conditions  ·  Drugs  ·  Sponsors  ·  

A Single Centre Study of the Feasibility and Safety of Using Ex-vivo Normothermic Machine Perfusion With the Organox Metra™ Device to Store Human Livers for Transplantation

RegistryNCT02478151
StatusUnknown
PhasePhase 1
Study typeInterventional; na, single group, masking: none, other
Enrollment40 (Estimated)
SponsorUniversity Health Network, Toronto (Other)
ConditionsEnd-stage Liver Disease
InterventionsOrganOx Metra (Device)
Datesstart 2015-07-01, primary completion 2022-12-01 (estimated), completion 2023-03-31 (estimated), first posted 2015-06-23, last updated 2022-04-12
Locations1 site in Canada

Related Papers Related Patents Related Grants Related Experts
AI Assistant Save
All trials for End-stage Liver Disease All trials of OrganOx Metra

-Summary

This trial will examine the safety and feasibility of using the OrganOx Metra device to transport and store donor livers under normothermic conditions prior to transplantation. Participants will be followed for 3 months following transplantation and their outcomes recorded.

Expand all sections  ·  Collapse all

+Detailed description

Liver transplantation is a life-saving procedure but its success has been limited by a shortage of suitable donor organs. Much emphasis is now placed on optimising the condition of those organs that are available, to enable more higher risk organs to be transplanted safely. An effective means of pre-transplant viability assessment would not only allow greater use of higher risk donors but also minimise the risk of primary non-function by identifying and excluding non-viable organs before subjecting a patient to the risk of surgery. Organ storage under normothermic perfusion conditions enables organ function to be evaluated prior to transplantation and further has been shown to prevent organ injury which is sustained during standard cold storage. This trial will examine the safety and feasibility of using the OrganOx Metra device to transport and store donor livers under normothermic conditions prior to transplantation. This study will evaluate liver function post-transplantation using standard clinical parameters. Participants will be followed for 3 months following transplantation and their outcomes recorded. Participants will undergo no other study procedures. Feasibility will be measured using the ratio of actual / eligible candidate donors recruited to the study and will also encompass logistical issues with respect to transportation, and ease of use. Safety will be assessed by rates of device failures resulting in organ discard, primary graft non-function, re-transplantation, and recipient death.

+Arms and interventions

ArmTypeInterventionsDescription
OrganOx MetraExperimentalDevice: OrganOx MetraOrganOx Metra Device
  • OrganOx Metra (Device): Normothermic machine perfusion (NMP) Metra device

+Outcome measures

Primary outcomes

  • Rates of primary graft non-function [3 months]
  • Rates of re-transplantation [3 months]
  • Rates of recipient death [3 months]

Secondary outcomes

  • Rate of device failures resulting in organ discard [3 months]
  • Recruitment rates to the study [3 months]: Measured by the ratio of actual / eligible candidate donors recruited to the study
  • Ischemia- reperfusion injury associated with organ storage [7 days]: Assessed by a post-perfusion biopsy
  • Ischemia- reperfusion injury associated with organ storage [7 days]: Assessed by measuring the peak serum aspartate transaminase level (AST) within 7 days post-transplant
  • The function of liver grafts stored with the Metra™ device [3 months]: Measured by bilirubin, alkaline phosphatase, AST and INR levels at days 1-7 post-transplant. The measure is a composite.
  • The function of liver grafts stored with the Metra™ device [3 months]: Measured by bilirubin, alkaline phosphatase, AST and INR levels at day 30 post-transplant. The measure is a composite.
  • The function of liver grafts stored with the Metra™ device [3 months]: Measured by bilirubin, alkaline phosphatase, AST and INR levels at month 3 post-transplant. The measure is a composite.
  • The function of liver grafts stored with the Metra™ device [3 months]: Measured by Lactate at days 1-3 post-transplant. The measure is a composite.
  • The ability of perfusion parameters to predict clinical outcomes following transplantation [3 months]: Perfusion flows and pressures will be studied to determine their correlation with graft injury and function. The measure is a composite.
  • The ability of perfusion parameters to predict clinical outcomes following transplantation [3 months]: Perfusate blood gas parameters will be studied to determine their correlation with graft injury and function. The measure is a composite.
  • The ability of perfusion parameters to predict clinical outcomes following transplantation [3 months]: Bile production will be studied to determine their correlation with graft injury and function

+Eligibility

Sex: All, ages: 18 Years to 70 Years

Inclusion Criteria:

* Adult patients (18 years or more)
* Active on the waiting list for liver transplantation
* Able to give informed consent

Exclusion Criteria:

* Age less than 18 years
* Acute/fulminant liver failure
* Transplantation of more than one organ (e.g. liver and kidney)
* Refusal of informed consent
* Unable to give informed consent
* Re-transplantation Diagnosis of Hepatopulmonary Syndrome