The Vascutek Custom Fenestrated Anaconda Post-Market Surveillance Study

NCT01826344 — Terminated, 628 participants, Vascutek Ltd.

ClinicalTrials Daily  ·  Areas  ·  Conditions  ·  Drugs  ·  Sponsors  ·  
RegistryNCT01826344
StatusTerminated
Study typeObservational
Enrollment628 (Actual)
SponsorVascutek Ltd. (Industry)
ConditionsAbdominal Aortic Aneurysms (AAA)
Datesstart 2010-06-01, primary completion 2015-12-01, completion 2015-12-01, first posted 2013-04-08, last updated 2015-12-09
Locations71 sites in Austria, Belgium, Canada, France, Germany, Italy, Monaco, Netherlands and 4 more countries

Related Papers Related Patents Related Grants Related Experts
All trials for Abdominal Aortic Aneurysms (AAA)

-Summary

This is a multicentre, prospective, observational post-market registry (follow-up 1 month, 1 year, 2 years, 3 years, 4 years and 5 years) to monitor the post-market clinical safety and effectiveness of the Vascutek AnacondaTM Custom Fenestrated Stent Graft in patients with a short infrarenal neck of <15mm or juxta-renal abdominal aortic aneurysms who, in the opinion of the treating physician, are anatomically suitable for the AnacondaTM Custom Fenestrated Stent Graft and for whom a customised medical device is required.

Expand all sections  ·  Collapse all

+Detailed description

AnacondaTM Custom Fenestrated Devices (CFD) are designed for the endovascular repair of abdominal aortic aneurysms (AAA) for cases where the aneurysm extends superiorly very close to or involving the renal arteries, leaving insufficient neck length for infrarenal device sealing. The non-CE marked devices are custom designed based on CT scan data of the patient's aorta and regulated in accordance with the Medical Device Directive (93/42/EEC) and associated country specific regulations as applicable.

The proximal end of the AnacondaTM fenestrated body device is positioned suprarenally, where it seals and fixates in the vessel by means of rings comprised of multiple turns of fine nitinol wire, attached to the fabric with polyester sutures, creating a self-expanding stent which provides a conformable seal with the vessel wall and assists in anchoring of the device. Nitinol hooks provide secure fixation within the suprarenal aorta. The saddle shape of the rings allows the superior mesenteric artery (SMA) or celiac artery to be accommodated in the valley of the top ring saddle in some cases.

The objective of the registry is to provide long term (5 year) safety and effectiveness data of all patients who consent to their data to be used in the registry. This data aims to demonstrate that the Vascutek AnacondaTM Custom Fenestrated Stent Graft is safe and effective in patients with a short infrarenal neck of <15mm or juxta-renal abdominal aortic aneurysms who, in the opinion of the treating physician, are anatomically suitable for the AnacondaTM Custom Fenestrated Stent Graft.

+Outcome measures

Primary outcomes

  • To monitor the the post-market clinical safety and effectiveness of the Vascutek AnacondaTM Custom Fenestrated Stent Graft [For 5 years post-implant]: To monitor the post-market clinical safety and effectiveness of the Vascutek AnacondaTM Custom Fenestrated Stent Graft in patients with a short infrarenal neck of <15mm or juxta-renal abdominal aortic aneurysms who, in the opinion of the treating physician, are anatomically suitable for the AnacondaTM Custom Fenestrated Stent Graft and for whom a customised medical device is required.

+Eligibility

Sex: All, ages: 18 Years to any

Inclusion Criteria:

A patient with juxta renal abdominal aortic aneurysms (AAA) who, in the opinion of the treating physician, is anatomically suitable for the Anaconda Fenestrated Graft and for whom a customised medical device is required.

Exclusion Criteria:

1. Ruptured or symptomatic aneurysm
2. Clinically significant concomitant medical disease or infection
3. Connective Tissue Disease (e.g. Marfan's Syndrome)
4. Known allergy to nitinol, polyester or contrast medium
5. Excessive tortuosity of access vessels (femoral or iliac arteries)
6. Landing zone of less than 10mm in the visceral segment of the aorta
7. Inability to comply to follow up protocol
8. Access vessels less than 6mm in diameter
9. Diseased or excessively tortuous access to target vessels
10. Target vessels of less than 5mm in calibre
11. Excessive calcification or thrombus at the intended landing zone which could affect sealing

+Locations (71)

FacilityCityCountryStatus
Kaiser Franz Josef SpitalViennaAustria
Krankenhaus HietzingViennaAustria
Imelda HospitalBonheidenBelgium
St Luc BrusselsBrusselsBelgium
University Hospital, BrusselsBrusselsBelgium
Grand Hôpital de CharleroiCharleroiBelgium
H.-Hartziekenhuis Roeselare-MenenRoeselareBelgium
Peter Lougheed CentreCalgaryCanada
QE2 HospitalHalifaxCanada
London Health Sciences CentreLondon, OntarioCanada
Royal Victoria HospitalMontrealCanada
The Ottawa HospitalOttawaCanada
St Clare's Mercy HospitalSt. JohnsCanada
Toronto General HospitalTorontoCanada
Health Science CentreWinnipegCanada
Hopital PellegrinBordeauxFrance
CHU Henri MondorCréteilFrance
Chirurgien VasculaireDraguignanFrance
Clinique Ambrose ParéNancyFrance
La PitieParisFrance
Le Plessis RobinsonParisFrance
CHU ToursToursFrance
Luisenhospital - AachenAachenGermany
University Hospital AachenAachenGermany
Klinikum AugsburgAugsburgGermany
Red Cross hospital clinicBremenGermany
University of CologneCologneGermany
Klinikum Frankfurt HochstFrankfurtGermany
Universitatsklinikum FreiburgFreiburg im BreisgauGermany
Krankenhaus FreitalFreitalGermany
Chirurgie am WaldwegGöttingenGermany
University of GroningenGröningenGermany
Asklepios Klinik AltonaHamburgGermany
Medical Care Centre for Vascular DiseasesHammGermany
MarienhospitalKevelaerGermany
Bonifacius HospitalLingenGermany
University HospitalMunichGermany
DRK Krankenhaus NeustrelitzNeustrelitzGermany
Krankenhaus Barmherzige BruderRegensburgGermany
University HospitalRegensburgGermany
Klinikum SolingenSolingenGermany
Marien-Hospital WittenWittenGermany
University of BolognaBolognaItaly
Ospedale San FrancescoNuoroItaly
Azienda Ospedaliera Ospedali Riuniti Villa Sofia CervelPalermoItaly
San Filippo Neri HospitalRomeItaly
Centre Cardio ThoraciqueMonacoMonaco
Jeroen Bosch Hospital's-HertogenboschNetherlands
Medisch Spectrum TwenteEnschedeNetherlands
Maastricht University Medical CentreMaastrichtNetherlands
Erasmus UniversityRotterdamNetherlands
Isala KliniekenZwolleNetherlands
Hospital DonostiaDonostia / San SebastianSpain
Hospital Universitario La PazMadridSpain
Hospital de NavarraPamplonaSpain
Hospital Universitari Parc TauliSabadellSpain
Uppsala UniversityUppsalaSweden
University Hospital BernBernSwitzerland
Kantonsspital GraubundenChurSwitzerland
Royal Derby HospitalDerbyUnited Kingdom
Frimley Park HospitalFrimleyUnited Kingdom
Western Infirmary/GartnavelGlasgowUnited Kingdom
Leeds General InfirmaryLeedsUnited Kingdom
Leicester Royal InfirmaryLeicesterUnited Kingdom
Imperial (St Mary's / Charing X) HospitalLondonUnited Kingdom
Kings College HospitalLondonUnited Kingdom
The Royal Free HospitalLondonUnited Kingdom
The Royal London HospitalLondonUnited Kingdom
Freeman HospitalNewcastleUnited Kingdom
John Radcliffe HospitalOxfordUnited Kingdom
Royal Preston HospitalPrestonUnited Kingdom