Brazilian and Italian Evaluation of Safety Using Tacrolimus-eluting Stent With Short-term Dual Antiplatelet Regimen

NCT01122719 — Not applicable, Terminated, 16 participants, CID - Carbostent & Implantable Devices

ClinicalTrials Daily  ·  Areas  ·  Conditions  ·  Drugs  ·  Sponsors  ·  

The Best Trial - Brazilian and Italian Evaluation of Safety Using Tacrolimus-eluting Stent With Short-term Dual Antiplatelet Regimen

RegistryNCT01122719, acronym BEST
StatusTerminated - slow inclusion, due to difficulties in obtaining the patients consent for the 2 months invasive follow-up, as required by protocol design.
PhaseNot applicable
Study typeInterventional; non randomized, single group, masking: none, treatment
Enrollment16 (Actual)
SponsorCID - Carbostent & Implantable Devices (Industry); collaborators: Contract research Organization: Cardiovascular Research Center - Sao Paulo, Brazil
ConditionsStable Coronary Disease, Unstable Coronary Disease, Documented Silent Ischemia
InterventionsDrug Eluting Stent (Device)
Datesstart 2010-10-01, primary completion 2011-11-01, completion 2013-03-01, first posted 2010-05-13, last updated 2018-05-07
Locations2 sites in Brazil, Italy

Related Papers Related Patents Related Grants Related Experts
All trials for Stable Coronary Disease All trials for Unstable Coronary Disease All trials of Drug Eluting Stent

-Summary

To evaluate the safety and efficacy of the Janus OPTIMA Tacrolimus-Eluting Stent (Optima TES, CID) for the treatment of de novo coronary lesions when associated with short-term (two months) dual antiplatelet (aspirin + clopidogrel) regimen.

Expand all sections  ·  Collapse all

+Detailed description

The present study is a post-market, prospective, international, two-center, single arm study involving 60 patients with single, de novo non-complex coronary lesions.

Enrolled patients will be asked to return for follow-up clinical evaluation at 1, 6, 12 and 24 months. At 3 months there will be an additional follow-up by phone contact.

Furthermore, the first 15 patients should undergo angiographic and OCT follow-up at two months. The remaining 45 patients should undergo angiographic and IVUS follow-up at 8 months.

+Arms and interventions

  • Drug Eluting Stent (Device)

+Outcome measures

Primary outcomes

  • In-stent late lumen loss [8-month]

Secondary outcomes

  • All-cause and cardiac mortality; [up to 24 months]
  • Myocardial infarction (MI): Q-wave and non-Q-wave, cumulative and individual [up to 24 months]
  • Major Adverse Cardiac Event (MACE) defined as a composite of cardiac death, MI (Q wave or non-Q wave), emergent coronary artery bypass surgery (CABG), or target lesion revascularization (TLR) by repeat PTCA or CABG [up to 24 months]
  • Rate of stent thrombosis using ARC definition of definite and probable stent thrombosis and categorized as early, late or very late [up to 24 months]
  • Stent strut coverage assessed by OCT [2 months]
  • Late acquired incomplete stent apposition by IVUS [8-month]
  • In stent & In segment angiographic parameters [8-month]
  • Clinically Driven TLR [up to 24 months]
  • Clinically Driven TVR [up to 24 months]
  • Target Lesion Failure (TLF) defined as cardiac death, MI and ischemic Target Lesion Revascularization (TLR) [up to 24 months]

+Eligibility

Sex: All, ages: 18 Years to any

Inclusion Criteria:

* Patient with >18 years of age;
* Symptoms of stable or unstable angina and/or presence of a positive functional test for ischemia;
* Presence of a single de novo target lesion located in a native coronary vessel suitable for percutaneous treatment with the study stents;
* Acceptable candidate for coronary artery bypass graft(CABG)surgery;
* The subject is willing to sign a written informed consent prior to procedure, and is willing to undergo ALL study protocol follow-ups,including angiographic, IVUS and OCT assessments.
* Single, de novo lesion
* Target lesion located in a major epicardial coronary vessel with reference of 2.5-3.5mm in diameter (by on-line QCA)
* Target lesions ≤19mm in length (by visual estimation) that can be treated (covered) by one single study stent (19 or 24mm in length);
* ≥50% and <100% diameter stenosis;
* TIMI (Thrombolysis In Myocardial Infarction) flow grade ≥2.

Exclusion Criteria:

* Known hypersensitivity or contraindication to tacrolimus, heparin,any required medications including thienopyridines, and contrast media which cannot be adequately pre medicated;
* Patient is a female with childbearing potential;
* Pre-treatment of the target lesion with any devices other than balloon angioplasty;
* Previous brachytherapy in the target vessel;
* Presence of non-target vessel lesions which require staged procedure(s) <30 days of the index procedure;
* Prior CABG surgery to target vessel;
* Previous percutaneous coronary intervention (PCI) or CABG surgery <30 days to the index procedure date;
* Acute myocardial infarction <3 days, with cardiac enzyme elevation including total creatine kinase (CK) >2 times the upper normal limit value and/or CK-MB above the upper normal limit value within the past 72 hours;
* CK and/or CK-MB levels elevated above the upper normal limit value at the time of the index procedure;
* Documented left ventricular ejection fraction <30%;
* Renal insufficiency determined by a baseline serum creatinine >2.0 mg/dl;
* Thrombocytopenia with a baseline platelet count <100,000 cells/mm3;
* Anemia with baseline hemoglobin <10g/dL;
* Extensive peripheral vascular disease or extreme anticoagulation that precludes safe >5 French sheath insertion;
* History of bleeding diathesis, coagulopathy, or refusal of blood transfusions;
* Patients has suffered a stroke, transient ischemic attack (TIA),or cerebrovascular accident (CVA) within the past 6 months;
* Significant gastrointestinal or genitourinary bleed within the past 6 months;
* Patient is a recipient of a heart transplant;
* Any elective surgical procedure is planned within 12 months of the index procedure;
* Known illness or any serious clinical condition with life expectancy <2 years;
* Participation in the active or follow-up phase of any other clinicaltrial within 6 months;
* Impossibility to comply with anti-platelet therapy during the study clinical follow-up;
* Any impossibility to comply with all protocol follow-ups.
* Target lesion or vessel with angiographic evidence of moderate or severe calcification;
* Presence of severe tortuosity;
* Presence of severe angulation (>60o);
* Presence of intraluminal thrombus;
* Target lesion involving a bifurcation (side branch ≥2.0mm);
* Target lesion located in the left main stem;
* Aorto-ostial lesion location;
* Target lesion involving a side branch with reference diameter≥2.0mm;
* Presence of a significant stenosis (>40%) in the target vessel either proximal or distal to the target lesion that will be untreated;
* Previous placement of a stent within 10mm of the target lesion;
* Total occlusion (TIMI flow grade 0 or 1);
* Target lesion located in an arterial or vein graft;
* Target lesion due to in-stent restenosis;
* Coronary anatomy unsuitable for percutaneous treatment with implantation of the available study stents.

+Locations (2)

FacilityCityCountryStatus
Istituto Dante PazzaneswSão PauloBrazil
Azienda Ospedaliera Universitaria di FerraraFerraraItaly

+Investigators